Full Product Manual
ELECTRIC POWER SUPPLY REQUIREMENTS 
• Your range must be electrically grounded in accordance with local codes or, in the 
absence of local codes, in accordance with the National Electrical Code (ANSI/NFPA 
70, latest edition). A copy of this standard may be obtained from the National Fire 
Protection Association. 
• The power supply must be the correct polarity. Reverse polarity will result in 
continuous sparking of the electrodes, even after flame ignition. If there is any doubt 
as to whether the power supply has the correct polarity or grounding, have it checked 
by a qualified electrician. 
• Use 120V, 60Hz, properly grounded branch circuit protected by a 15-amp or 
20-amp circuit breaker or time delay fuse. 
• A separate circuit, servicing only this appliance is required. 
WARNING: Never use reductions, shunts, extension cords or adapters which can 
cause overheating or burning.
• Place the power outlet so that it is accessible after the appliance has been installed. 
WARNING: Disconnect the appliance from the main power supply before installation 
or service. 
GROUNDING
• The power cord is equipped with a three-prong (grounding) plug which mates with 
a standard three-prong grounding wall receptacle to minimize the possibility of 
electrical shock hazard from the range. 
WARNING: DO NOT cut or remove the grounding prong from the power cord. 
• Where a standard two-prong wall receptacle is encountered, it is the responsibility 
and obligation of the customer to have it replaced with a properly grounded 
three-prong wall receptacle by a licensed electrician. 
• All cord connected appliances shall include instructions relative to location of the 
wall receptacle and a warning to the user to disconnect the electrical supply before 
serving the appliance.
WARNING: Make sure the AC Supply cable does not come in contact with any parts 
or components that get hot.
• The manufacturer is not liable for any direct or indirect damage caused by faulty 
installation or connection.
Area allows for flush 
installation with 
through-the-wall 
connection of pipe stub 
/ shut-off valve and rear 
wall 120V outlet.
Area allows for flush installation 
with through-the-floor connection 
of pipe stub / shut-off valve.
Shortest connection from 
hard pipe stub location to 
range hook-up.
14