GridVis® software - device confi guration
Basic settings
1. Right-click to open the context menu for
your device:
- In the "Projects" > "Your project“ >
"Devices" > "By device type" >
"UMG 96-PA" > "Device x" window.
2. Click the "Confi guration" menu item in the
context menu.
3. The "Confi guration [Device x]"
window is displayed in the right
half of the work area.
4. Enter your individual device name in the
„Name“ input fi eld in the "Identity" menu in
the "Confi guration" window.
5. Enter the voltage and current ratios in the
input fi elds in the "Transformer" menu in
the "Confi guration" window.
6. Select the nominal frequency under
the "Nominal values" menu in the
"Confi guration" window, in accordance
with the existing grid conditions.
NOTE!
To avoid data loss, save your changes
to the device confi guration by pressing
"Transfer" or "Transfer to"!
GridVis software
®
quick-start guide
UMG 96-PA
Supplement to user manual and to installation instructions
Janitza electronics GmbH
Vor dem Polstück 6
D-35633 Lahnau / Germany
Support tel. +49 6441 9642-22
Fax +49 6441 9642-30
e-mail: info@janitza.com
www.janitza.com
General
This quick-start guide for our GridVis
®
software
is an addendum to the user manual and to the
installation instructions for the UMG 96-PA.
The following steps describe the most common
connections for communication between PC and
device.
Firstly, please read and understand the informa-
tion documents that accompanied the product
and in particular the safety-relevant information
contained within.
Disclaimer
Observing the information products for the
devices is the prerequisite for safe operation and
in order to obtain the specifi ed performance and
product features. Janitza electronics GmbH ac-
cepts no liability for injuries to personnel, property
damage or fi nancial losses arising due to a failure
to comply with the information products.
Ensure that your information products are acces-
sible and legible.
Further documentation is available on our website
at www.janitza.de under
Support > Downloads.
Copyright notice
© 2017 - Janitza electronics GmbH - Lahnau.
All rights reserved. Duplication, editing, dis-
semination and other utilisation, also in part, is
prohibited.
Subject to technical changes.
Information and specifi cations may change.
Please obtain information on the current ver-
sion of our software from www.janitza.de.
SAFETY
Please observe the safety instructions in this
document, which are shown as follows and
that include the following degree of hazard for
our software:
m
CAUTION!
Indicates hazardous situations,
that could lead to property dam-
age due to data loss or faults in
the IT network for example.
This symbol with the word
NOTE! describes important informa-
tion, procedures or handling steps.
3
5
Establish the connection to the PC
The most common connections for communication
between the PC and the device:
m
CAUTION!
Damage to property due to
incorrect network settings
Incorrect network settings can cause faults in
the IT network!
Obtain information from your network
administrator about the correct Ethernet
network settings for your device.
Fig. Rear side of UMG 96-PA
1.
(gedrehtes Patchkabel)
RS485
PC/
GridVis®
RS485
RS485
Device connection
via interface converter.
RS232
RS232
2.
(gedrehtes Patchkabel)
USB
RS485
RS485
RS485
Device connection
via interface converter.
USB
PC/
GridVis®
(gedrehtes Patchkabel)
3.
Connection of the device
via a UMG 604 as a gateway.
UMG 604
RS485
Ethernet
RS485
PC/
GridVis®
UMG 96-PA
UMG 96-PA
UMG 96-PA
UMG 96-PA
UMG 96-PA
UMG 96-PA
UMG 96-PA - PC connection via UMG 604 as gateway
The PC connection of the UMG 96-PA via the
UMG 604 as gateway is the most common
connection between PC and device:
1. Confi gure your UMG 604 via Ethernet cable
on your PC in the network with DHCP server
as “DHCP Client” (IP address assigned
automatically), without DHCP server as “Fixed
IP address” (see user manual and installation
instructions for the UMG 604).
2. Connect your UMG 96-PA with the UMG
604 via the RS485 interface (see installation
instructions).
GridVis® software
Install the GridVis® software on your computer and
proceed as follows:
1. Open the GridVis® software on your PC.
2. In the menu bar, select "File" >
"New project". If the project already exists,
open it by selecting "File" >
"Open project“.
3. The "New project" window is displayed.
4. In step 1, "Select project", click "Continue".
5. In step 2, "Project path", select the:
- “Project name”.
- “Project path”.
Insert UMG 604 in the project:
1. In the menu bar, select "File" >
"New fi le".
2. The "New fi le" window is displayed.
3. In step 1, "Select fi le type", select the "File
type" (UMG 604) in the "DIN Rail" category.
4. Click "Next".
5. The "Confi gure connection"
step is displayed in the window.
6. Click "Finish".
7. Your project is displayed on the left in the
"Projects" window in the work area.
6. In the "Connection type" selection list, select
"TCP/IP" and enter the IP address for your
device in the "Host" fi eld.
The IP address of your UMG 604 is determined
via the parameter addresses 300 to 303 in
programming mode (see user manual and
installation instructions for the UMG 604).
7. Click "Connection test”.
8. If the connection test is successful, the "Display
device information" window appears with the
serial number, hardware version and fi rmware
version.
9. Click "OK".
10. Complete the "Insert new device into the
project" step by clicking "Finish".
Insert UMG 96-PA in the project:
1. Click in the project window on the plus
symbol in front of the "Devices" directory.
2. Click on the plus symbol in front of the
"By device type" subdirectory in the
"Devices" directory.
3. The UMG 604 that was installed previously
is displayed.
4. Right-click with the mouse on the
"By device type" subdirectory.
5. Select the "New" menu item in the context
menu.
6. Click on the "Other" menu item in the sub-
menu.
8. In the "UMG 96 Series" category,
select the "File type” UMG 96-PA.
7. The "New fi le" window is displayed.
9. Click "Next".
10. The "Confi gure connection"
step is displayed in the window.
11. Important settings in "Confi gure connection":
- In the selection list, select the "Ethernet
gateway (e.g. for devices on the RS485)"
connection type.
- Enter the IP address of your UMG 604
in the "Address" input fi eld (read out
parameter addresses 300 to 303 on the
device).
- In the "Device address" selection fi eld,
select the device address for your UMG
96-PA (see user manual and installation
instructions for the UMG 96-PA).
12. Click "Connection test".
13. If the connection test is successful, the
"Display device information" window appears
with the serial number, hardware version and
fi rmware version.
14. Click "OK".
15. Complete the "Insert new device into the
project" step by clicking "Finish".
NOTE!
The GridVis
®
device confi guration and
recording settings describe the basic
settings.
The program windows shown may dif-
fer from the actual display depending
on the device.
Additional functions, information and
device settings specially for your
device can be found in the GridVis®
software's online help.
In "Recording confi guration", you can check and
confi gure which recordings the measurement
device should save if required.
A record holds a measured value or the mean
value of the measured value.
GridVis® software - recording settings
Download area:
Deutsche Version:
Siehe Vorderseite
1
2
www.janitza.com
Doc. no. 2.061.013.0
Art. no. 33.03.361
4
GridVis® software - device confi guration
Basic settings
1. Right-click to open the context menu for
your device:
- In the "Projects" > "Your project“ >
"Devices" > "By device type" >
"UMG 96-PA" > "Device x" window.
2. Click the "Confi guration" menu item in the
context menu.
3. The "Confi guration [Device x]"
window is displayed in the right
half of the work area.
4. Enter your individual device name in the
„Name“ input fi eld in the "Identity" menu in
the "Confi guration" window.
5. Enter the voltage and current ratios in the
input fi elds in the "Transformer" menu in
the "Confi guration" window.
6. Select the nominal frequency under
the "Nominal values" menu in the
"Confi guration" window, in accordance
with the existing grid conditions.
NOTE!
To avoid data loss, save your changes
to the device confi guration by pressing
"Transfer" or "Transfer to"!
GridVis software
®
quick-start guide
UMG 96-PA
Supplement to user manual and to installation instructions
Janitza electronics GmbH
Vor dem Polstück 6
D-35633 Lahnau / Germany
Support tel. +49 6441 9642-22
Fax +49 6441 9642-30
e-mail: info@janitza.com
www.janitza.com
General
This quick-start guide for our GridVis
®
software
is an addendum to the user manual and to the
installation instructions for the UMG 96-PA.
The following steps describe the most common
connections for communication between PC and
device.
Firstly, please read and understand the informa-
tion documents that accompanied the product
and in particular the safety-relevant information
contained within.
Disclaimer
Observing the information products for the
devices is the prerequisite for safe operation and
in order to obtain the specifi ed performance and
product features. Janitza electronics GmbH ac-
cepts no liability for injuries to personnel, property
damage or fi nancial losses arising due to a failure
to comply with the information products.
Ensure that your information products are acces-
sible and legible.
Further documentation is available on our website
at www.janitza.de under
Support > Downloads.
Copyright notice
© 2017 - Janitza electronics GmbH - Lahnau.
All rights reserved. Duplication, editing, dis-
semination and other utilisation, also in part, is
prohibited.
Subject to technical changes.
Information and specifi cations may change.
Please obtain information on the current ver-
sion of our software from www.janitza.de.
SAFETY
Please observe the safety instructions in this
document, which are shown as follows and
that include the following degree of hazard for
our software:
m
CAUTION!
Indicates hazardous situations,
that could lead to property dam-
age due to data loss or faults in
the IT network for example.
This symbol with the word
NOTE! describes important informa-
tion, procedures or handling steps.
3
5
Establish the connection to the PC
The most common connections for communication
between the PC and the device:
m
CAUTION!
Damage to property due to
incorrect network settings
Incorrect network settings can cause faults in
the IT network!
Obtain information from your network
administrator about the correct Ethernet
network settings for your device.
Fig. Rear side of UMG 96-PA
1.
(gedrehtes Patchkabel)
RS485
PC/
GridVis®
RS485
RS485
Device connection
via interface converter.
RS232
RS232
2.
(gedrehtes Patchkabel)
USB
RS485
RS485
RS485
Device connection
via interface converter.
USB
PC/
GridVis®
(gedrehtes Patchkabel)
3.
Connection of the device
via a UMG 604 as a gateway.
UMG 604
RS485
Ethernet
RS485
PC/
GridVis®
UMG 96-PA
UMG 96-PA
UMG 96-PA
UMG 96-PA
UMG 96-PA
UMG 96-PA
UMG 96-PA - PC connection via UMG 604 as gateway
The PC connection of the UMG 96-PA via the
UMG 604 as gateway is the most common
connection between PC and device:
1. Confi gure your UMG 604 via Ethernet cable
on your PC in the network with DHCP server
as “DHCP Client” (IP address assigned
automatically), without DHCP server as “Fixed
IP address” (see user manual and installation
instructions for the UMG 604).
2. Connect your UMG 96-PA with the UMG
604 via the RS485 interface (see installation
instructions).
GridVis® software
Install the GridVis® software on your computer and
proceed as follows:
1. Open the GridVis® software on your PC.
2. In the menu bar, select "File" >
"New project". If the project already exists,
open it by selecting "File" >
"Open project“.
3. The "New project" window is displayed.
4. In step 1, "Select project", click "Continue".
5. In step 2, "Project path", select the:
- “Project name”.
- “Project path”.
Insert UMG 604 in the project:
1. In the menu bar, select "File" >
"New fi le".
2. The "New fi le" window is displayed.
3. In step 1, "Select fi le type", select the "File
type" (UMG 604) in the "DIN Rail" category.
4. Click "Next".
5. The "Confi gure connection"
step is displayed in the window.
6. Click "Finish".
7. Your project is displayed on the left in the
"Projects" window in the work area.
6. In the "Connection type" selection list, select
"TCP/IP" and enter the IP address for your
device in the "Host" fi eld.
The IP address of your UMG 604 is determined
via the parameter addresses 300 to 303 in
programming mode (see user manual and
installation instructions for the UMG 604).
7. Click "Connection test”.
8. If the connection test is successful, the "Display
device information" window appears with the
serial number, hardware version and fi rmware
version.
9. Click "OK".
10. Complete the "Insert new device into the
project" step by clicking "Finish".
Insert UMG 96-PA in the project:
1. Click in the project window on the plus
symbol in front of the "Devices" directory.
2. Click on the plus symbol in front of the
"By device type" subdirectory in the
"Devices" directory.
3. The UMG 604 that was installed previously
is displayed.
4. Right-click with the mouse on the
"By device type" subdirectory.
5. Select the "New" menu item in the context
menu.
6. Click on the "Other" menu item in the sub-
menu.
8. In the "UMG 96 Series" category,
select the "File type” UMG 96-PA.
7. The "New fi le" window is displayed.
9. Click "Next".
10. The "Confi gure connection"
step is displayed in the window.
11. Important settings in "Confi gure connection":
- In the selection list, select the "Ethernet
gateway (e.g. for devices on the RS485)"
connection type.
- Enter the IP address of your UMG 604
in the "Address" input fi eld (read out
parameter addresses 300 to 303 on the
device).
- In the "Device address" selection fi eld,
select the device address for your UMG
96-PA (see user manual and installation
instructions for the UMG 96-PA).
12. Click "Connection test".
13. If the connection test is successful, the
"Display device information" window appears
with the serial number, hardware version and
fi rmware version.
14. Click "OK".
15. Complete the "Insert new device into the
project" step by clicking "Finish".
NOTE!
The GridVis
®
device confi guration and
recording settings describe the basic
settings.
The program windows shown may dif-
fer from the actual display depending
on the device.
Additional functions, information and
device settings specially for your
device can be found in the GridVis®
software's online help.
In "Recording confi guration", you can check and
confi gure which recordings the measurement
device should save if required.
A record holds a measured value or the mean
value of the measured value.
GridVis® software - recording settings
Download area:
Deutsche Version:
Siehe Vorderseite
1
2
www.janitza.com
Doc. no. 2.061.013.0
Art. no. 33.03.361
4
GridVis® software - device confi guration
Basic settings
1. Right-click to open the context menu for
your device:
- In the "Projects" > "Your project“ >
"Devices" > "By device type" >
"UMG 96-PA" > "Device x" window.
2. Click the "Confi guration" menu item in the
context menu.
3. The "Confi guration [Device x]"
window is displayed in the right
half of the work area.
4. Enter your individual device name in the
„Name“ input fi eld in the "Identity" menu in
the "Confi guration" window.
5. Enter the voltage and current ratios in the
input fi elds in the "Transformer" menu in
the "Confi guration" window.
6. Select the nominal frequency under
the "Nominal values" menu in the
"Confi guration" window, in accordance
with the existing grid conditions.
NOTE!
To avoid data loss, save your changes
to the device confi guration by pressing
"Transfer" or "Transfer to"!
GridVis software
®
quick-start guide
UMG 96-PA
Supplement to user manual and to installation instructions
Janitza electronics GmbH
Vor dem Polstück 6
D-35633 Lahnau / Germany
Support tel. +49 6441 9642-22
Fax +49 6441 9642-30
e-mail: info@janitza.com
www.janitza.com
General
This quick-start guide for our GridVis
®
software
is an addendum to the user manual and to the
installation instructions for the UMG 96-PA.
The following steps describe the most common
connections for communication between PC and
device.
Firstly, please read and understand the informa-
tion documents that accompanied the product
and in particular the safety-relevant information
contained within.
Disclaimer
Observing the information products for the
devices is the prerequisite for safe operation and
in order to obtain the specifi ed performance and
product features. Janitza electronics GmbH ac-
cepts no liability for injuries to personnel, property
damage or fi nancial losses arising due to a failure
to comply with the information products.
Ensure that your information products are acces-
sible and legible.
Further documentation is available on our website
at www.janitza.de under
Support > Downloads.
Copyright notice
© 2017 - Janitza electronics GmbH - Lahnau.
All rights reserved. Duplication, editing, dis-
semination and other utilisation, also in part, is
prohibited.
Subject to technical changes.
Information and specifi cations may change.
Please obtain information on the current ver-
sion of our software from www.janitza.de.
SAFETY
Please observe the safety instructions in this
document, which are shown as follows and
that include the following degree of hazard for
our software:
m
CAUTION!
Indicates hazardous situations,
that could lead to property dam-
age due to data loss or faults in
the IT network for example.
This symbol with the word
NOTE! describes important informa-
tion, procedures or handling steps.
3
5
Establish the connection to the PC
The most common connections for communication
between the PC and the device:
m
CAUTION!
Damage to property due to
incorrect network settings
Incorrect network settings can cause faults in
the IT network!
Obtain information from your network
administrator about the correct Ethernet
network settings for your device.
Fig. Rear side of UMG 96-PA
1.
(gedrehtes Patchkabel)
RS485
PC/
GridVis®
RS485
RS485
Device connection
via interface converter.
RS232
RS232
2.
(gedrehtes Patchkabel)
USB
RS485
RS485
RS485
Device connection
via interface converter.
USB
PC/
GridVis®
(gedrehtes Patchkabel)
3.
Connection of the device
via a UMG 604 as a gateway.
UMG 604
RS485
Ethernet
RS485
PC/
GridVis®
UMG 96-PA
UMG 96-PA
UMG 96-PA
UMG 96-PA
UMG 96-PA
UMG 96-PA
UMG 96-PA - PC connection via UMG 604 as gateway
The PC connection of the UMG 96-PA via the
UMG 604 as gateway is the most common
connection between PC and device:
1. Confi gure your UMG 604 via Ethernet cable
on your PC in the network with DHCP server
as “DHCP Client” (IP address assigned
automatically), without DHCP server as “Fixed
IP address” (see user manual and installation
instructions for the UMG 604).
2. Connect your UMG 96-PA with the UMG
604 via the RS485 interface (see installation
instructions).
GridVis® software
Install the GridVis® software on your computer and
proceed as follows:
1. Open the GridVis® software on your PC.
2. In the menu bar, select "File" >
"New project". If the project already exists,
open it by selecting "File" >
"Open project“.
3. The "New project" window is displayed.
4. In step 1, "Select project", click "Continue".
5. In step 2, "Project path", select the:
- “Project name”.
- “Project path”.
Insert UMG 604 in the project:
1. In the menu bar, select "File" >
"New fi le".
2. The "New fi le" window is displayed.
3. In step 1, "Select fi le type", select the "File
type" (UMG 604) in the "DIN Rail" category.
4. Click "Next".
5. The "Confi gure connection"
step is displayed in the window.
6. Click "Finish".
7. Your project is displayed on the left in the
"Projects" window in the work area.
6. In the "Connection type" selection list, select
"TCP/IP" and enter the IP address for your
device in the "Host" fi eld.
The IP address of your UMG 604 is determined
via the parameter addresses 300 to 303 in
programming mode (see user manual and
installation instructions for the UMG 604).
7. Click "Connection test”.
8. If the connection test is successful, the "Display
device information" window appears with the
serial number, hardware version and fi rmware
version.
9. Click "OK".
10. Complete the "Insert new device into the
project" step by clicking "Finish".
Insert UMG 96-PA in the project:
1. Click in the project window on the plus
symbol in front of the "Devices" directory.
2. Click on the plus symbol in front of the
"By device type" subdirectory in the
"Devices" directory.
3. The UMG 604 that was installed previously
is displayed.
4. Right-click with the mouse on the
"By device type" subdirectory.
5. Select the "New" menu item in the context
menu.
6. Click on the "Other" menu item in the sub-
menu.
8. In the "UMG 96 Series" category,
select the "File type” UMG 96-PA.
7. The "New fi le" window is displayed.
9. Click "Next".
10. The "Confi gure connection"
step is displayed in the window.
11. Important settings in "Confi gure connection":
- In the selection list, select the "Ethernet
gateway (e.g. for devices on the RS485)"
connection type.
- Enter the IP address of your UMG 604
in the "Address" input fi eld (read out
parameter addresses 300 to 303 on the
device).
- In the "Device address" selection fi eld,
select the device address for your UMG
96-PA (see user manual and installation
instructions for the UMG 96-PA).
12. Click "Connection test".
13. If the connection test is successful, the
"Display device information" window appears
with the serial number, hardware version and
fi rmware version.
14. Click "OK".
15. Complete the "Insert new device into the
project" step by clicking "Finish".
NOTE!
The GridVis
®
device confi guration and
recording settings describe the basic
settings.
The program windows shown may dif-
fer from the actual display depending
on the device.
Additional functions, information and
device settings specially for your
device can be found in the GridVis®
software's online help.
In "Recording confi guration", you can check and
confi gure which recordings the measurement
device should save if required.
A record holds a measured value or the mean
value of the measured value.
GridVis® software - recording settings
Download area:
Deutsche Version:
Siehe Vorderseite
1
2
www.janitza.com
Doc. no. 2.061.013.0
Art. no. 33.03.361
4
GridVis® software - device confi guration
Basic settings
1. Right-click to open the context menu for
your device:
- In the "Projects" > "Your project“ >
"Devices" > "By device type" >
"UMG 96-PA" > "Device x" window.
2. Click the "Confi guration" menu item in the
context menu.
3. The "Confi guration [Device x]"
window is displayed in the right
half of the work area.
4. Enter your individual device name in the
„Name“ input fi eld in the "Identity" menu in
the "Confi guration" window.
5. Enter the voltage and current ratios in the
input fi elds in the "Transformer" menu in
the "Confi guration" window.
6. Select the nominal frequency under
the "Nominal values" menu in the
"Confi guration" window, in accordance
with the existing grid conditions.
NOTE!
To avoid data loss, save your changes
to the device confi guration by pressing
"Transfer" or "Transfer to"!
GridVis software
®
quick-start guide
UMG 96-PA
Supplement to user manual and to installation instructions
Janitza electronics GmbH
Vor dem Polstück 6
D-35633 Lahnau / Germany
Support tel. +49 6441 9642-22
Fax +49 6441 9642-30
e-mail: info@janitza.com
www.janitza.com
General
This quick-start guide for our GridVis
®
software
is an addendum to the user manual and to the
installation instructions for the UMG 96-PA.
The following steps describe the most common
connections for communication between PC and
device.
Firstly, please read and understand the informa-
tion documents that accompanied the product
and in particular the safety-relevant information
contained within.
Disclaimer
Observing the information products for the
devices is the prerequisite for safe operation and
in order to obtain the specifi ed performance and
product features. Janitza electronics GmbH ac-
cepts no liability for injuries to personnel, property
damage or fi nancial losses arising due to a failure
to comply with the information products.
Ensure that your information products are acces-
sible and legible.
Further documentation is available on our website
at www.janitza.de under
Support > Downloads.
Copyright notice
© 2017 - Janitza electronics GmbH - Lahnau.
All rights reserved. Duplication, editing, dis-
semination and other utilisation, also in part, is
prohibited.
Subject to technical changes.
Information and specifi cations may change.
Please obtain information on the current ver-
sion of our software from www.janitza.de.
SAFETY
Please observe the safety instructions in this
document, which are shown as follows and
that include the following degree of hazard for
our software:
m
CAUTION!
Indicates hazardous situations,
that could lead to property dam-
age due to data loss or faults in
the IT network for example.
This symbol with the word
NOTE! describes important informa-
tion, procedures or handling steps.
3
5
Establish the connection to the PC
The most common connections for communication
between the PC and the device:
m
CAUTION!
Damage to property due to
incorrect network settings
Incorrect network settings can cause faults in
the IT network!
Obtain information from your network
administrator about the correct Ethernet
network settings for your device.
Fig. Rear side of UMG 96-PA
1.
(gedrehtes Patchkabel)
RS485
PC/
GridVis®
RS485
RS485
Device connection
via interface converter.
RS232
RS232
2.
(gedrehtes Patchkabel)
USB
RS485
RS485
RS485
Device connection
via interface converter.
USB
PC/
GridVis®
(gedrehtes Patchkabel)
3.
Connection of the device
via a UMG 604 as a gateway.
UMG 604
RS485
Ethernet
RS485
PC/
GridVis®
UMG 96-PA
UMG 96-PA
UMG 96-PA
UMG 96-PA
UMG 96-PA
UMG 96-PA
UMG 96-PA - PC connection via UMG 604 as gateway
The PC connection of the UMG 96-PA via the
UMG 604 as gateway is the most common
connection between PC and device:
1. Confi gure your UMG 604 via Ethernet cable
on your PC in the network with DHCP server
as “DHCP Client” (IP address assigned
automatically), without DHCP server as “Fixed
IP address” (see user manual and installation
instructions for the UMG 604).
2. Connect your UMG 96-PA with the UMG
604 via the RS485 interface (see installation
instructions).
GridVis® software
Install the GridVis® software on your computer and
proceed as follows:
1. Open the GridVis® software on your PC.
2. In the menu bar, select "File" >
"New project". If the project already exists,
open it by selecting "File" >
"Open project“.
3. The "New project" window is displayed.
4. In step 1, "Select project", click "Continue".
5. In step 2, "Project path", select the:
- “Project name”.
- “Project path”.
Insert UMG 604 in the project:
1. In the menu bar, select "File" >
"New fi le".
2. The "New fi le" window is displayed.
3. In step 1, "Select fi le type", select the "File
type" (UMG 604) in the "DIN Rail" category.
4. Click "Next".
5. The "Confi gure connection"
step is displayed in the window.
6. Click "Finish".
7. Your project is displayed on the left in the
"Projects" window in the work area.
6. In the "Connection type" selection list, select
"TCP/IP" and enter the IP address for your
device in the "Host" fi eld.
The IP address of your UMG 604 is determined
via the parameter addresses 300 to 303 in
programming mode (see user manual and
installation instructions for the UMG 604).
7. Click "Connection test”.
8. If the connection test is successful, the "Display
device information" window appears with the
serial number, hardware version and fi rmware
version.
9. Click "OK".
10. Complete the "Insert new device into the
project" step by clicking "Finish".
Insert UMG 96-PA in the project:
1. Click in the project window on the plus
symbol in front of the "Devices" directory.
2. Click on the plus symbol in front of the
"By device type" subdirectory in the
"Devices" directory.
3. The UMG 604 that was installed previously
is displayed.
4. Right-click with the mouse on the
"By device type" subdirectory.
5. Select the "New" menu item in the context
menu.
6. Click on the "Other" menu item in the sub-
menu.
8. In the "UMG 96 Series" category,
select the "File type” UMG 96-PA.
7. The "New fi le" window is displayed.
9. Click "Next".
10. The "Confi gure connection"
step is displayed in the window.
11. Important settings in "Confi gure connection":
- In the selection list, select the "Ethernet
gateway (e.g. for devices on the RS485)"
connection type.
- Enter the IP address of your UMG 604
in the "Address" input fi eld (read out
parameter addresses 300 to 303 on the
device).
- In the "Device address" selection fi eld,
select the device address for your UMG
96-PA (see user manual and installation
instructions for the UMG 96-PA).
12. Click "Connection test".
13. If the connection test is successful, the
"Display device information" window appears
with the serial number, hardware version and
fi rmware version.
14. Click "OK".
15. Complete the "Insert new device into the
project" step by clicking "Finish".
NOTE!
The GridVis
®
device confi guration and
recording settings describe the basic
settings.
The program windows shown may dif-
fer from the actual display depending
on the device.
Additional functions, information and
device settings specially for your
device can be found in the GridVis®
software's online help.
In "Recording confi guration", you can check and
confi gure which recordings the measurement
device should save if required.
A record holds a measured value or the mean
value of the measured value.
GridVis® software - recording settings