Tus neeg siv phau ntawv

4. Disassemblethelightxtureandreplacelampas
follows:
Be sure to keep the special pilot screw from this
underwater light. This screw mounts and electrically
grounds the housing securely to the mounting ring
and wet niche. Failure to use the screw provided
could create an electrical hazard, which could result
in death or serious injury to pool or spa users,
installers or others due to electrical shock.
WARNING
a. Loosen the eight (8) Phillips head screws for pool
lightorthesix(6)Phillipsheadscrewsforspa
light to allow the bottom clamp to be removed
from the face ring assembly. Do not remove the
screws or the retaining rings. The retaining rings
prevent the screws from falling free from the top
clamp and also aid in ease of assembly.
b. Remove the lower clamp, the face ring assembly,
theglasslens,andthegasketfromthefixture.
Remove the gasket from the lens. Refer to Section
4, Exploded View and Replacement Parts.
c. Install new lamp.
Risk of Electrical Shock or Electrocution. Always
install a new lens gasket whenever disassembling
the light (for Jandy Pool Light Gasket P/N
R0451101 and for Jandy Spa Light Gasket P/N
R0400501). Failure to do so may permit water to
leak into the assembly, which could cause:
(a) An electrical hazard resulting in death or serious
injury to pool or spa users, installers, or others
due to electrical shock, or
(b) Breakage of the lamp or lens, which likewise
could result in serious injury to pool or spa users,
installers, or bystanders, or in damage to
property.
WARNING
5. Reassemblethextureasfollows:
a. If not already done, remove the gasket from the
glass lens and install a new gasket, Jandy Pool
Light Gasket (P/N R0451101) and Jandy Spa
Light Gasket (P/N R0400501), on the lens.
NOTE A new lens gasket must be used each time the
light is reassembled.
b. Whileholdingthefixtureupright,placetheglass
lenswiththegasketontopofthefixture.Please
note that the lens gasket is not symmetrical.
Therefore, it must be installed correctly so that
thelenscansealtothefixturehousing.Placethe
gasket on the lens so that the thick molded side
of the gasket will mate with the housing when the
lens is installed. See Figure 5.
c. Positionthelensandgasketonthefixture.Place
the face ring and the top clamp over the lens and
align the pilot screw with the small arrow mark
on the face of the lens. Note that the small arrow
mark on the face of the lens and the pilot screw
of the face ring must be aligned with the arrow
locatedonfixturelabelthatreads,“Arrowonthis
label must line up with the pilot screw on the Face
Ring”. See Figure 2.
d. While holding the aligned face ring assembly and
fixturetogether,turntheassemblyupsidedown
and set it on the old gasket, using the old gasket
asanassemblyfixture.Thiswillkeepthelensand
gasket assembly from being pushed out of the face
ringwhileyousecureittothelightfixture.
e. Spread the bottom clamp over the electrical cord
andslideitontothebackoffixturetothetop
clamp. See Figure 2.
f. Tighten the eight (8) Phillips head screws for pool
lightorthesix(6)Phillipsheadscrewsforspa
light in alternating cross-pattern. Torque screws to
approximately20in-lbs.Donotover-tighten.
g. Discard the old gasket.
6. ReinstalltheJandyLightintonichexture.
a. Coilfour(4)feetofcordaroundthefixtureand
place the light assembly into the niche.
b. Engage the retainer tab on the bottom of the face
ring,thenpivotthetopofthefixtureinwardand
tighten the special pilot screw.
Page 6
ENGLISH
Jandy
®
Pro Series Underwater Pool and Spa White Lights
|
Operation Manual