User Manual
Page 10
ENGLISH
Jandy
®
Versa-Plumb
®
Cartridge Pool Filters
|
Installation & Operation Manual
10. If desired, the CV lter drain can be plumbed
using a Jandy Pro universal union. The plumbing
must contain a ball valve as shown in Figure 6.
CAUTION
Be sure that all provisions for wastewater disposal
meet local, state or national codes. During any
draining process, one hundred gallons (100 gals.)
or more of pool water will be discharged. CL and CV
(Cartridge) Filters are not subject to backwashing. Do
not discharge water where it will cause flooding or
damage.
3.5 Clamp Installation
1. Be certain the o-ring is in position in the lower
tank half. Press the lter lid over the lower half
sandwiching the o-ring between the two halves.
2. Holding the ends of the lter clamp apart,
position the hinged segment of the lter clamp
over both upper and lower tank anges. Bring the
ends of the lter clamp together.
3. Place the "T" nut and threaded rod assembly into
the clamp. Be sure the "T" nut is seated in the
clamp in the proper orientation. See Fig. 9.
4. Use a 9/16" socket on the tightening nut until
the clamp ring halves touch each other, or are
within 1/16", see Fig. 9
but do not overtighten
as the clamp can break. If unable to tighten
as indicated, do not operate the lter and
call a
service technician immediately.
5. After the rst week of operation, check the clamp
and retighten if necessary.
6. Check the lter clamp at least once a month.
Figure 9. Filter Clamp Ring
Clamp Ring
"T" Nut and
Threaded Rod
Tightening Nut
w/ Shoulder
WARNING
Follow these instructions carefully.
Improper clamp installation can
cause product failure or also cause
the filter lid to be blown off, which
can result in death, serious personal
injury, or property damage.
Section 4. Start-Up and
Operation
NOTE This section applies to both new pool and
seasonal start-up.
1. Turn off the pump. Switch off the circuit breaker
to the pump motor.
2. Check that the drain plug for CL lters or drain
cap for CV lters is in place and tight.
3. Check that the tank clamp is correctly seated and
tight. See Figs. 9 and 10.
WARNING
NEVER start pump while standing
within five (5) feet of the filter. Starting
the pump while there is pressurized air
in the system can cause product failure
or also cause the filter lid to be blown
off, which can cause death, serious
personal injury or property damage.
WARNING
NEVER operate the filter system
at more than 50 psi of pressure.
Operating the filter system in excess
of 50 psi can cause the product failure
or also cause filter lid to be blown
off, which can cause death, serious
personal injury or property damage.
CAUTION
DO NOT operate filter at water temperatures above
105° F (40.6° C). Water temperatures above the
manufacturer’s recommendations will shorten the life
span of the filter and void the warranty.
4. Open the pump hair/lint pot lid and ll the pump
basket with water to prime the system. Replace
the lid. (You may have to do this several times on
new and seasonal start-ups.)
5. Completely open the air release valve on
the gauge/air release assembly by turning
the knob on the back of the assembly fully
counterclockwise (do not remove the knob).