Installation Guide

Passes ANSI A118.10 waterproofness.
100%
WATERPROOF
CEMENT
BOARD.
Installation Guide
FOR WALLS, FLOORS AND COUNTERTOPS
1 | English
CUTTING HARDIEBACKER
CUTTING HARDIEBACKER
®
®
CEMENT
CEMENT
BOARD
BOARD
WITH HYDRODEFENSE
WITH HYDRODEFENSE
TECHNOLOGY
TECHNOLOGY
Use a straight edge as a guide to score the board’s face and snap upward along
the score line. We recommend using a carbide tipped scoring knife, but a utility
knife may also be used. The use of shears (manual, electric or pneumatic) is also
acceptable.
For cutouts and small holes, score around perimeter and break out from the face
side with hammer.
Using high-speed power tools (e.g. saws, grinders, etc.) to cut James Hardie
®
products may generate excessive silica dust.
NEVER cut James Hardie products indoors with these tools.
ALWAYS cut outside with adequate ventilation and/or dust collection
equipment in accordance with OSHA regulations.
To further limit respirable silica dust exposures, wear a properly-fitted NIOSH
approved dust mask or respirator (e.g. N-95 dust mask) in accordance with
applicable government regulations and manufacturer instructions.
NEVER dry sweep – Use wet dust suppression methods, sweeping compound, or
use a vacuum to collect dust.
WALL INSTALLATION
WALL INSTALLATION
1 | Ensure the framing is structurally sound
• Framing shall comply with local building codes and ANSI A108.11.
Use a minimum of 2 in. x 4 in. wood studs or 20-gauge metal studs, which
must be straight, properly aligned and spaced a maximum of 16 in. on center.
In tub and shower enclosures, ensure that the framing is adequately
reinforced at the corners and ends.
SPECIFICATIONS
SPECIFICATIONS
• Thickness: 0.42 in.
• Dimensions: 36 in. x 60 in.
• Weight: 2.6 lb/sq. ft.
• Application: Walls, floors & countertops
English | 2
WALL INSTALLATION
WALL INSTALLATION
(Continued)
(Continued)
2 | Determine the HardieBacker
®
Cement Board with HydroDefense
Technology layout
• Boards may be installed vertically or horizontally.
Edges of the board parallel to framing must be supported by a structural
framing member.
• Score and snap boards to required sizes and make necessary cutouts.
3 | Attach the HardieBacker
®
Cement Board with HydroDefense
Technology to framing
HardieBacker
®
Cement Board with HydroDefense
Technology has internal
waterproofing treatments. Does not require a moisture barrier.*
Attach the HardieBacker
®
Cement Board with HydroDefense
Technology.
Provide a 1/4 in. clearance gap between the floor, tub or shower receptor
base and the cement board.
• Do not place cement board into the shower pan mortar bed.
Fasten the product with specified nails or screws (as listed in “Materials
Required”) a maximum of 8 in. on center at all supports.
Keep fasteners 3/8 in. from board edges and 2 in. in from sheet corners.
Set fastener heads flush with the surface, without overdriving.
4 | Joints and Penetrations
Seal fixture penetrations, plumbing penetrations and abutments to dissimilar
materials with flexible sealant (see “Materials Required”).
Fill all joints with mortar (see “Materials Required”). While mortar is still
workable, embed minimum 2 in. wide high-strength alkali-resistant glass
fiber tape in the mortar and level.
• Do not use all-purpose joint compound or paper tape.
When complete waterproofing is required, seal all joints, edges and fastener
penetrations with a liquid waterproofing membrane. Follow the liquid
waterproofing membrane manufacturer application instructions.
* Some application areas may require additional waterproofing. Refer to local building code requirements.

Summary of content (8 pages)