Installation Guide
Passes ANSI A118.10 waterproofness.
100%
WATERPROOF
CEMENT
BOARD.
Installation Guide
FOR WALLS, FLOORS AND COUNTERTOPS
1 | English
CUTTING HARDIEBACKER
CUTTING HARDIEBACKER
®
®
CEMENT
CEMENT
BOARD
BOARD
WITH HYDRODEFENSE
WITH HYDRODEFENSE
™
™
TECHNOLOGY
TECHNOLOGY
• Use a straight edge as a guide to score the board’s face and snap upward along
the score line. We recommend using a carbide tipped scoring knife, but a utility
knife may also be used. The use of shears (manual, electric or pneumatic) is also
acceptable.
• For cutouts and small holes, score around perimeter and break out from the face
side with hammer.
• Using high-speed power tools (e.g. saws, grinders, etc.) to cut James Hardie
®
products may generate excessive silica dust.
NEVER cut James Hardie products indoors with these tools.
ALWAYS cut outside with adequate ventilation and/or dust collection
equipment in accordance with OSHA regulations.
To further limit respirable silica dust exposures, wear a properly-fitted NIOSH
approved dust mask or respirator (e.g. N-95 dust mask) in accordance with
applicable government regulations and manufacturer instructions.
• NEVER dry sweep – Use wet dust suppression methods, sweeping compound, or
use a vacuum to collect dust.
WALL INSTALLATION
WALL INSTALLATION
1 | Ensure the framing is structurally sound
• Framing shall comply with local building codes and ANSI A108.11.
• Use a minimum of 2 in. x 4 in. wood studs or 20-gauge metal studs, which
must be straight, properly aligned and spaced a maximum of 16 in. on center.
• In tub and shower enclosures, ensure that the framing is adequately
reinforced at the corners and ends.
SPECIFICATIONS
SPECIFICATIONS
• Thickness: 0.42 in.
• Dimensions: 36 in. x 60 in.
• Weight: 2.6 lb/sq. ft.
• Application: Walls, floors & countertops
English | 2
WALL INSTALLATION
WALL INSTALLATION
(Continued)
(Continued)
2 | Determine the HardieBacker
®
Cement Board with HydroDefense
™
Technology layout
• Boards may be installed vertically or horizontally.
• Edges of the board parallel to framing must be supported by a structural
framing member.
• Score and snap boards to required sizes and make necessary cutouts.
3 | Attach the HardieBacker
®
Cement Board with HydroDefense
™
Technology to framing
• HardieBacker
®
Cement Board with HydroDefense
™
Technology has internal
waterproofing treatments. Does not require a moisture barrier.*
• Attach the HardieBacker
®
Cement Board with HydroDefense
™
Technology.
• Provide a 1/4 in. clearance gap between the floor, tub or shower receptor
base and the cement board.
• Do not place cement board into the shower pan mortar bed.
• Fasten the product with specified nails or screws (as listed in “Materials
Required”) a maximum of 8 in. on center at all supports.
• Keep fasteners 3/8 in. from board edges and 2 in. in from sheet corners.
• Set fastener heads flush with the surface, without overdriving.
4 | Joints and Penetrations
• Seal fixture penetrations, plumbing penetrations and abutments to dissimilar
materials with flexible sealant (see “Materials Required”).
• Fill all joints with mortar (see “Materials Required”). While mortar is still
workable, embed minimum 2 in. wide high-strength alkali-resistant glass
fiber tape in the mortar and level.
• Do not use all-purpose joint compound or paper tape.
• When complete waterproofing is required, seal all joints, edges and fastener
penetrations with a liquid waterproofing membrane. Follow the liquid
waterproofing membrane manufacturer application instructions.
* Some application areas may require additional waterproofing. Refer to local building code requirements.