Full Product Manual

114
Store flat and keep dry and covered prior to
installation. Installing siding wet or saturated may
result in shrinkage at butt joints. Carry planks on
edge. Protect edges and corners from breakage.
James Hardie is not responsible for damage caused
by improper storage and
handling of the
product.
OUTDOORS
1. Position cutting station so that airflow blows dust away from the
user and others near the cutting area.
2. Cut using one of the following methods:
a. Best: Circular saw equipped with a HardieBlade
®
saw blade
and attached vacuum dust collection system. Shears
(manual, pneumatic or electric) may also be used, not
recommended for products thicker than 7/16 in.
b. Better: Circular saw equipped with a dust collection feature
(e.g. Roan
®
saw) and a HardieBlade saw blade.
c. Good: Circular saw equipped with a HardieBlade saw blade.
INDOORS
DO NOT grind or cut with a power saw indoors. Cut using shears (manual, pneumatic or
electric) or the score and snap method, not recommended for products thicker than 7/16 in.
- DO NOT dry sweep dust; use wet dust suppression or vacuum to collect dust.
- For maximum dust reduction, James Hardie recommends using the “Best” cutting
practices. Always follow the equipment manufacturer’s instructions for proper operation.
- For best performance when cutting with a circular saw, James Hardie recommends
using HardieBlade
®
saw blades.
- Go to jameshardiepros.com for additional cutting and dust control recommendations.
CUTTING INSTRUCTIONS
STORAGE & HANDLING:
IMPORTANT: The Occupational Safety and Health Administration (OSHA) regulates workplace exposure to silica dust. For construction sites, OSHA has deemed
that cutting fiber cement with a circular saw having a blade diameter less than 8 inches and connected to a commercially available dust collection system per
manufacturer’s instructions results in exposures below the OSHA Permissible Exposure Limit (PEL) for respirable crystalline silica, without the need for additional
respiratory protection.
If you are unsure about how to comply with OSHA silica dust regulations, consult a qualified industrial hygienist or safety professional, or contact your James
Hardie technical sales representative for assistance. James Hardie makes no representation or warranty that adopting a particular cutting practice will assure
your compliance with OSHA rules or other applicable laws and safety requirements.
GENERAL REQUIREMENTS:
These instructions to be used for single family installations only. **For Commercial / Multi-Family installation
requirements go to www.JamesHardieCommercial.com
HardiePanel
®
vertical siding can be installed over braced wood or steel studs, 20 gauge (33 mils) minimum to 16
gauge (54 mils) maximum, spaced a maximum of 24 in o.c. or directly to minimum 7/16 in thick OSB sheathing. See
General Fastening Requirements. Irregularities in framing and sheathing can mirror through the finished application.
Correct irregularities before installing siding.
Information on installing James Hardie products over non-nailable substrates (ex: gypsum, foam,etc.) can be located
in JH Tech Bulletin 19 at www.jamehardie.com
A water-resistive barrier is required in accordance with local building code requirements. The water-resistive barrier
must be appropriately installed with penetration and junction flashing in accordance with local building code
requirements. James Hardie will assume no responsibility for water infiltration. James Hardie does manufacture
HardieWrap
®
Weather Barrier, a non-woven non-perforated housewrap¹, which complies with building code
requirements.
Adjacent finished grade must slope away from the building in accordance with local building codes - typically a
minimum of 6 in. in the first 10 ft.
Do not use HardiePanel lap siding in Fascia or Trim applications.
Do not install James Hardie products, such that they may remain in contact with standing water.
HardiePanel vertical siding may be installed on flat vertical wall applications only.
For larger projects, including commercial and multi-family projects, where the span of the wall is significant in length,
the designer and/or architect should take into consideration the coefficient of thermal expansion and moisture
movement of the product in their design. These values can be found in the Technical Bulletin “Expansion Characteristics
of James Hardie
®
Siding Products” at www.jameshardie.com.
• James Hardie Building Products provides installation /wind load information for buildings with a maximum mean roof
height of 85 feet. For information on installations above 60 feet, please contact JH technical support.
• Minimum standard panel design size is 12" x 16". Note:Panels may be notched and cut to size to fit between windows,
doors, corners, etc.
IMPORTANT: FAILURE TO FOLLOW JAMES HARDIE WRITTEN INSTALLATION INSTRUCTIONS AND COMPLY WITH APPLICABLE BUILDING CODES MAY VIOLATE LOCAL LAWS, AFFECT
BUILDING ENVELOPE PERFORMANCE AND MAY AFFECT WARRANTY COVERAGE. FAILURE TO COMPLY WITH ALL HEALTH AND SAFETY REGULATIONS WHEN CUTTING AND INSTALLING
THIS PRODUCT MAY RESULT IN PERSONAL INJURY. BEFORE INSTALLATION, CONFIRM YOU ARE USING THE CORRECT HARDIEZONE® PRODUCT INSTRUCTIONS BY VISITING
HARDIEZONE.COM OR CALL 1-866-942-7343 (866-9-HARDIE)
Visit jameshardiepros.com for the most recent version.
EFFECTIVE SEPTEMBER 2019
SMOOTH | CEDARMILL
©
| STUCCO | SIERRA 8
HardiePanel
®
Vertical Siding
SINGLE FAMILY INSTALLATION REQUIREMENTS
HS1237 P1/3 09/19
Figure 3
Figure 4
Recommendation: When
installing Sierra 8, provide
a double stud at panel
joints to avoid nailing
through grooves.
upper panel
1/4" gap
Z-flashing
Do not
Caulk
lower
panel
upper panel
1/4" gap
Z-flashing
Do not
Caulk
lower
panel
decorative
band board
water-resistive
barrier
water-resistive
barrier
*Apply caulk in accordance with caulk manufacturer’s written application instructions.
¹For additional information on HardieWrap™ Weather Barrier, consult James Hardie at 1-866-4Hardie or www.hardiewrap.com
**James Hardie recommends installing a rainscreen (an air gap) between the HardiePanel siding and the water-resistive barrier as a best practice.
James Hardie recommends that you consult your design professional if you have questions regarding the use of rainscreen on your single family project.
Figure 1
Figure 2
Caulk Joint
leave appropriate gap between
panels, then caulk*
water-resistive barrier
2 x 4 stud
“H” Joint
water-resistive barrier
2 x 4 stud
Batten Joint
water-resistive barrier
2 x 4 stud
moderate contact
water-resistive
barrier
HardiePanel
vertical siding
2 in
3/8 in
sheathing
(Caulking Joints is
not applicable to
ColorPlus
®
Finish)
INSTALLATION:
Fastener
Joint Treatment
Position fasteners 3/8 in from panel edges and no closer than 2 in
away from corners. Do not nail into corners.
• HardiePanel vertical siding must be joined on stud.
• Double stud may be required to maintain minimum edge
nailing distances.
• When screws are used to attach panels to steel studs/furring, the
screws shall have wing tips. If screws do not have wing tips, then
pre-drilling is required. (Not applicable when using pins) Follow
chart below for pre-drilling:
Vertical Joints - Install panels in moderate contact (fig. 1),
alternatively joints may also be covered with battens, PVC or metal
jointers or caulked (Not applicable to ColorPlus
®
Finish) (fig. 2).
• Horizontal Joints - Provide Z-flashing at all horizontal joints (fig. 3).
SCREW PRE-DRILL HEAD DIAMETER
No. 8 7/32 in Min 0.323 in
No. 10 1/4 in Min 0.323 in