User Manual
Table Of Contents
- M6e-31.5dBm Hardware Guide
- Contents
- Mercury6e Introduction
- Hardware Overview
- Firmware Overview
- Communication Protocol
- Functionality of the Mercury6e
- Appendix A: Error Messages
- Common Error Messages
- FAULT_MSG_WRONG_NUMBER_OF_DATA – (100h)
- FAULT_INVALID_OPCODE – (101h)
- FAULT_UNIMPLEMENTED_OPCODE – 102h
- FAULT_MSG_POWER_TOO_HIGH – 103h
- FAULT_MSG_INVALID_FREQ_RECEIVED (104h)
- FAULT_MSG_INVALID_PARAMETER_VALUE - (105h)
- FAULT_MSG_POWER_TOO_LOW - (106h)
- FAULT_UNIMPLEMENTED_FEATURE - (109h)
- FAULT_INVALID_BAUD_RATE - (10Ah)
- Bootloader Faults
- Flash Faults
- Protocol Faults
- FAULT_NO_TAGS_FOUND – (400h)
- FAULT_NO_PROTOCOL_DEFINED – 401h
- FAULT_INVALID_PROTOCOL_SPECIFIED – 402h
- FAULT_WRITE_PASSED_LOCK_FAILED – 403h
- FAULT_PROTOCOL_NO_DATA_READ – 404h
- FAULT_AFE_NOT_ON – 405h
- FAULT_PROTOCOL_WRITE_FAILED – 406h
- FAULT_NOT_IMPLEMENTED_FOR_THIS_PROTOCOL – 407h
- FAULT_PROTOCOL_INVALID_WRITE_DATA – 408h
- FAULT_PROTOCOL_INVALID_ADDRESS – 409h
- FAULT_GENERAL_TAG_ERROR – 40Ah
- FAULT_DATA_TOO_LARGE – 40Bh
- FAULT_PROTOCOL_INVALID_KILL_PASSWORD – 40Ch
- FAULT_PROTOCOL_KILL_FAILED - 40Eh
- FAULT_PROTOCOL_BIT_DECODING_FAILED - 40Fh
- FAULT_PROTOCOL_INVALID_EPC – 410h
- FAULT_PROTOCOL_INVALID_NUM_DATA – 411h
- FAULT_GEN2 PROTOCOL_OTHER_ERROR - 420h
- FAULT_GEN2_PROTOCOL_MEMORY_OVERRUN_BAD_PC - 423h
- FAULT_GEN2 PROTOCOL_MEMORY_LOCKED - 424h
- FAULT_GEN2 PROTOCOL_INSUFFICIENT_POWER - 42Bh
- FAULT_GEN2 PROTOCOL_NON_SPECIFIC_ERROR - 42Fh
- FAULT_GEN2 PROTOCOL_UNKNOWN_ERROR - 430h
- Analog Hardware Abstraction Layer Faults
- Tag ID Buffer Faults
- System Errors
- Common Error Messages
- Appendix B: Getting Started - Devkit
Demo Application
Appendix B: Getting Started - Devkit 77
Demo Application
A demo application which supports multi-protocol reading and writing is provided in the
MercuryAPI SDK package. The source code for this example is included in the
MercuryAPI SDK package under /cs/samples/M6e-Read-Write-Demo-Tool. See the
MercuryAPI Programming Guide for details on using the MercuryAPI.
Demo Tool Notes
The region is only changed upon initialization. You must disconnect the reader,
change the region, and then “Initialize Reader” to change this value.
The protocol search display is only updated when one of the “Read” buttons is
pressed, not when the choice is made via the pull-down menu
“Read on all connected antennas” automatically activates antenna detection and will
ignore ports with an undetectable antenna. To read on these ports, the antenna port
must be explicitly selected.
The “Total tags read in x seconds” display only works for the “Read Once” function,
not Start/Stop Reads.
When “Start Reads” is clicked the M6e will read for the specified timeout with a 2
second delay (RF off) between reads. It is not a continuous read.