User Manual
Table Of Contents
- M6e-31.5dBm Hardware Guide
- Contents
- Mercury6e Introduction
- Hardware Overview
- Firmware Overview
- Communication Protocol
- Functionality of the Mercury6e
- Appendix A: Error Messages
- Common Error Messages
- FAULT_MSG_WRONG_NUMBER_OF_DATA – (100h)
- FAULT_INVALID_OPCODE – (101h)
- FAULT_UNIMPLEMENTED_OPCODE – 102h
- FAULT_MSG_POWER_TOO_HIGH – 103h
- FAULT_MSG_INVALID_FREQ_RECEIVED (104h)
- FAULT_MSG_INVALID_PARAMETER_VALUE - (105h)
- FAULT_MSG_POWER_TOO_LOW - (106h)
- FAULT_UNIMPLEMENTED_FEATURE - (109h)
- FAULT_INVALID_BAUD_RATE - (10Ah)
- Bootloader Faults
- Flash Faults
- Protocol Faults
- FAULT_NO_TAGS_FOUND – (400h)
- FAULT_NO_PROTOCOL_DEFINED – 401h
- FAULT_INVALID_PROTOCOL_SPECIFIED – 402h
- FAULT_WRITE_PASSED_LOCK_FAILED – 403h
- FAULT_PROTOCOL_NO_DATA_READ – 404h
- FAULT_AFE_NOT_ON – 405h
- FAULT_PROTOCOL_WRITE_FAILED – 406h
- FAULT_NOT_IMPLEMENTED_FOR_THIS_PROTOCOL – 407h
- FAULT_PROTOCOL_INVALID_WRITE_DATA – 408h
- FAULT_PROTOCOL_INVALID_ADDRESS – 409h
- FAULT_GENERAL_TAG_ERROR – 40Ah
- FAULT_DATA_TOO_LARGE – 40Bh
- FAULT_PROTOCOL_INVALID_KILL_PASSWORD – 40Ch
- FAULT_PROTOCOL_KILL_FAILED - 40Eh
- FAULT_PROTOCOL_BIT_DECODING_FAILED - 40Fh
- FAULT_PROTOCOL_INVALID_EPC – 410h
- FAULT_PROTOCOL_INVALID_NUM_DATA – 411h
- FAULT_GEN2 PROTOCOL_OTHER_ERROR - 420h
- FAULT_GEN2_PROTOCOL_MEMORY_OVERRUN_BAD_PC - 423h
- FAULT_GEN2 PROTOCOL_MEMORY_LOCKED - 424h
- FAULT_GEN2 PROTOCOL_INSUFFICIENT_POWER - 42Bh
- FAULT_GEN2 PROTOCOL_NON_SPECIFIC_ERROR - 42Fh
- FAULT_GEN2 PROTOCOL_UNKNOWN_ERROR - 430h
- Analog Hardware Abstraction Layer Faults
- Tag ID Buffer Faults
- System Errors
- Common Error Messages
- Appendix B: Getting Started - Devkit
Protocol Faults
62 Appendix A: Error Messages
FAULT_NO_TAGS_FOUND – (400h)
Cause
A command was received (such as like read, write, or lock) but the operation failed. There
are many reasons that can cause this error to occur.
Here is a list of possible reasons that could be causing this error:
No tag in the RF field
Read/write power too low
Antenna not connected
Tag is weak or dead
Solution
Make sure there is a good tag in the field and all parameters are set up correctly. The best
way to check this is to try few tags of the same type to rule out a weak tag. If none
passed, then it could be SW configuration such as protocol value, antenna, and so forth,
or a placement configuration like a tag location.
FAULT_NO_PROTOCOL_DEFINED – 401h
Cause
A command was received to perform a protocol command but no protocol was initially
set. The reader powers up with no protocols set.
Solution
A protocol must be set before the reader can begin RF operations.
FAULT_INVALID_PROTOCOL_SPECIFIED – 402h
Cause
The protocol value was set to a protocol that is not supported with the current version of
SW.