Protocol Faults
54
Here is a list of possible reasons that could be causing this error:
No tag in the RF field
Read/write power too low
Antenna not connected
Tag is we a k or dead
Solution
Make sure there is a good tag in the field and all parameters are set up correctly. The best way
to check this is to try few tags of the same type to rule out a weak tag. If none passed, then it
could be SW configuration such as protocol value, antenna, and so forth, or a placement
configuration like a tag location.
FAULT_NO_PROTOCOL_DEFINED – 401h
Cause
A command was received to perform a protocol command but no protocol was initially set. The
reader powers up with no protocols set.
Solution
A Set Current Tag Protocol (63h) command must be sent followed by resending the desired
command.
FAULT_INVALID_PROTOCOL_SPECIFIED – 402h
Cause
A Set Current Tag Protocol (63h) command was received for a protocol value that is not
supported with the current version of SW.
Solution
This value is invalid or this version of SW does not support the protocol value. Check the
documentation for the correct values for the protocols in use.