User Manual
Table Of Contents
- Communication Regulation Information
- Chapter 1: Introducing the Mercury Embedded Reader
- Chapter 2: Setting Up the Reader
- Chapter 3: Using the Reader Assistant
- Appendix A: Hardware Details
- Appendix B: Error Messages
- Common Error Messages
- FAULT_MSG_WRONG_NUMBER_OF_DATA - (100h)
- FAULT_INVALID_OPCODE - (101h)
- FAULT_UNIMPLEMENTED_OPCODE - 102h
- FAULT_MSG_POWER_TOO_HIGH - 103h
- FAULT_MSG_INVALID_FREQ_RECEIVED (104h)
- FAULT_MSG_INVALID_PARAMETER_VALUE - (105h)
- FAULT_MSG_POWER_TOO_LOW - (106h)
- FAULT_UNIMPLEMENTED_FEATURE - (109h)
- FAULT_INVALID_BAUD_RATE - (10Ah)
- Bootloader Faults
- Flash Faults
- Protocol Faults
- FAULT_NO_TAGS_FOUND - (400h)
- FAULT_NO_PROTOCOL_DEFINED - 401h
- FAULT_INVALID_PROTOCOL_SPECIFIED - 402h
- FAULT_WRITE_PASSED_LOCK_FAILED - 403h
- FAULT_PROTOCOL_NO_DATA_READ - 404h
- FAULT_AFE_NOT_ON - 405h
- FAULT_PROTOCOL_WRITE_FAILED - 406h
- FAULT_NOT_IMPLEMENTED_FOR_THIS_PROTOCOL - 407h
- FAULT_PROTOCOL_INVALID_WRITE_DATA - 408h
- FAULT_PROTOCOL_INVALID_ADDRESS - 409h
- FAULT_GENERAL_TAG_ERROR - 40Ah
- FAULT_DATA_TOO_LARGE - 40Bh
- FAULT_PROTOCOL_INVALID_KILL_PASSWORD - 40Ch
- FAULT_PROTOCOL_KILL_FAILED - 40Eh
- FAULT_GEN2 PROTOCOL_OTHER_ERROR - 420h
- FAULT_GEN2_PROTOCOL_MEMORY_OVERRUN_BAD_PC - 423h
- FAULT_GEN2 PROTOCOL_MEMORY_LOCKED - 424h
- FAULT_GEN2 PROTOCOL_INSUFFICIENT_POWER - 42Bh
- FAULT_GEN2 PROTOCOL_NON_SPECIFIC_ERROR - 42Fh
- FAULT_GEN2 PROTOCOL_UNKNOWN_ERROR - 430h
- Analog Hardware Abstraction Layer Faults
- Tag ID Buffer Faults
- System Errors
- Common Error Messages
- Appendix C: Antennas
- End User License and Warranty Agreement
Communication Settings
Chapter 3: Using the Reader Assistant 10
Communication Settings
You use the Communication Settings screen to set the Com Port and the baud rate. It can also
configure the baud rate used by the reader.
The Communication Settings screen displays automatically the first time the Reader Assistant is
launched. The Communication Settings screen also displays when the application settings file
application_settings.dat is deleted.
Otherwise, you can access the screen using the following procedure.
To access the Communication Settings screen:
1. Select Options > Communication Settings and the following dialog opens.
The Reader detects the COM Port that is on the computer system.
Note: If the Reader is attached to a different COM port, you have to choose the port from
the list.
2. From the Baud Rate menu, choose a communication rate. The default is 9600.
3. Click OK to close the Communications Settings screen.