PROBLEM PROBABLE CAUSES REMEDY
Contact Jacuzzi Luxury Bath @ 800-288-4002
Pump/motor does not start
Pump/motor shuts off by itself before time elapses
Chromatherapy lights do not operate
Pump/motor operates but no fully adjustable jets are 
functioning
Water leakage from pump unions
No power to pump/motor 
Pump/motor not plugged in 
Pump/motor faulty
Motor thermal protection has deactivated pump/motor 
due to overheating (supply voltage low)
GFCI tripped
Inadequate supply wiring
Reset GFCI 
Insert plug securely into outlet 
Ensure control panel is connected to control box 
Contact Jacuzzi Luxury Bath @ 800-288-4002
Let motor cool; thermal protection will reset. Check for 
proper ventilation (check supply voltage)
Reset GFCI. If it continues to trip, do not use this unit. 
Disconnect the unit and have the problem corrected by 
a licensed electrician before using.
Consult a licensed electrician to correct the wiring unit.
Connector has come loose
Jets are closed
Suction cover/strainer may be clogged
Open jets by rotating counter-clockwise
With the motor turned OFF, remove the suction cover/
strainer and remove any debris. Replace the suction 
cover before operating
Overtightened, O-ring may be pinched or improperly 
seated, undertightened
Loosen unions , check and reseat O-ring. If O-ring has 
been pinched out of shape, replace (refer to number 
below). When tightening union nuts, handtighten only.
Pump/motor operates but air is not injected into the 
water
Air valves are closed
Open air control valves
Drain assist purge cycle comes on multiple times
Blower does not start
Daily purge does not come on at specied time
Blower operates but NO air is exiting the holes
Blower shuts off unexpectedly
No power to pump/motor 
Blower not connected 
Blower faulty
Connector has come loose
Reset GFCI and/or breaker 
Ensure plug is fully in outlet 
Ensure control panel is connected to control box 
Ensure control box is connected to control panel 
Contact Jacuzzi Luxury Bath @ 800-288-4002
Set daily purge by holding down the ‘UP’ arrow for 5 
seconds
Purge not set (default setting is no purge)
Check valves are stuck in the closed position Contact Jacuzzi Luxury Bath @ 800-288-4002
20 minute timer has elapsed 
GFCI tripped 
Inadequate supply wiring 
Improper ventilation
Turn on blower 
Reset GFCI. If it continues, to trip, do not use the unit 
Consult a licensed electrician to correct 
Contact Jacuzzi Luxury Bath @ 800-288-4002
Blower operates but air is not exiting all of the holes Blower intensity is not sufcient 
Obstructed air holes
Increase the blower intensity. NOTE: The system is 
designed such that all air channels operate at the 4th 
blower setting. 
Remove debris with a toothpick or tooth brush
Contact Jacuzzi Luxury Bath @ 800-288-4002
Drain assist purge does not come on 5 minutes after 
bathtub is drained out completely
Water sensors detect multiple wet and dry conditions
Water sensors not connected and not detecting water 
being drained out of the tub 
Faulty control box
If during a purge, water is coming in contact with both 
sensors, the system is working as designed and will 
continue to purge until excess water is expelled
Remove any washcloth or toy that may be covering the 
sensors 
Contact Jacuzzi Luxury Bath @ 800-288-4002 
Contact Jacuzzi Luxury Bath @ 800-288-4002
Water not maintaining temperature High limit switch on heater has tripped Press Reset button on heater
Waterfall not working Whirlpool function not on
Waterfall control knob is in the OFF position
Debris in waterfall outlet
Turn on whirlpool
Turn waterfall control knob counter-clockwise until 
water ow is at the desired ow
Use a thin, rigid and non-abrasive material (ie. credit 
card) and gently swipe back and forth until debris is 
cleared away from the waterfall opening