Installation Sheet
j a c l o i n d u s t r i e s | 129 Dermody Street Cranford, NJ 07016
p 908.653.4433 | 800.852.3906 f 908.653.1717 | 800.852.4133
REVISED 8.10.2016
JACLO.COM
|
PG 3
FIGURE 5
HOT
COLD
Spout Installation
Note: Some items have been
pre-assembled at the factory to
ensure quality and t. Some
disassembly may be required
during installation.
1. Remove nut (14), washer (13) and
"T" if installed from spout mounting
nipple (15).
2. Slide spout assembly through
counter top or basin.
3. Slide washer (13) onto spout nipple
install nut (14) onto spout nipple and
secure spout onto counter top or
basin once positioned correctly.
4. Install "T" (16) onto nipple (15) using
a NSF listed joint compound.
Valve Installation
1. Identify hot and cold valves. Hot
has red ring and cold has blue ring.
2. Install hot valve on left side of spout
when facing sink. Figure 3
3. Install cold valve on right side of
spout when facing sink. Figure 3.
4. Remove handle, escutcheon, and
top valve nut.
5. Adjust lower valve nut (10) down
away from valve stem. Figure 4.
6. Place ber washer (9) on top of nut.
7. Find handle/escutcheon "A"
dimension. Figure 5.
8. Thread nut up towards stem so
distance from top of ber washer to
top of valve stem= "A" dimension +
counter or basin thickness.
9. Install valve through bottom of
counter or basin. Figure 4.
10. Install top nut and escutcheon on
to valve and tighten. *Note: not all
handle escutcheon combinations
use a top nut. Figure 5.
11. Conrm "A" dimension for faucet
model installed. Adjust if necessary.
FIGURE 1
FIGURE 3
FIGURE 4
FIGURE 2
Valve Stem
Counter or
Basin
Hose Installation
1. Connect hot hose to hot valve outlet
and "T". Figure 3.
2. Connect cold hose to cold valve
outlet and "T". Figure 3.
3. Connect supply hoses or tubes
(not supplied) to base of hot and
cold valves. Figure 4.
Aerator Cleaning
ALWAYS REMOVE AERATOR AND
FLUSH THE FAUCET AFTER
INITIAL INSTALLATION
1. Use aerator key supplied with faucet
2. Engage key in aerator. Figure 1.
3. Remove aerator by turning key
counterclockwise
4. Turn on hot and cold water valves
ush lines
5. Reinstall aerator by engaging key
and turning clockwise until tight
6. Check for leaks, re-tighten if
necessary
FIGURE 1
Aerator
Key
*No top nut used
on any of these
handles
1¼”-1½”Ø
1ӯ