Installation Sheet
j a c l o i n d u s t r i e s | 129 Dermody Street Cranford, NJ 07016
p 908.653.4433 f 908.653.1717 JACLO.COM
|
PG 2
REVISED 3.23.2020
VALVE COMPONENTS
VALVE COMPONENTS
ROUGH VALVE (6660-RGH)
PRE-INSTALL NOTES
This wall faucet can be installed with the spout and valve in any location. Installer must provide 1/2” street
elbows (if used) and piping from valve to spout.
*NOTE: NO EXTENSION AVAILABLE
VALVE ROUGH INSTALLATION
1. Determine location of spout and valve.
2. Build blocking for valve (2) to nished wall as per Figure 1. Front brass is 3/4” from nished wall
(critical). (No extension available)
3. If using at brass mount (Figure 3A), distance from cross beam to nish wall is 1 3/4” - 2 1/2”. If using
step mount (Figure 3B), distance from crossbeam to nished wall is 2 3/4 - 3 1/4”. Note: If using the
step mount for valve and putting the spout on same cross beam, it will be 1” shorter.
4. Attach spout and valve rough assembly to blocking with suitable fasterners. Figure 2
5. Remove cartridge lock nut (4) and cartridge (6). (DO NOT DISREGARD)
6. Plumb mixing valve attaching hot and cold water lines to inlets on valve. Figure 3
7. Reinstall cartridge (6) and cartridge locknut (4), put in off position, and turn on water supplies and
check for leaks.
Drop Ell (Spout Rough Assembly)
Valve Body
Mounting Bracket/Straight + Step provided
Cartridge Lock Nut (Retain for trim install)
Rough-in Collar
Cartridge
1
2
3A
3B