Blue Star C500 Static Single-phase Watt-hour Meter – IEC 61036 (1.0S) IEC 61036 IEC 1107 C500 Single-Phase Watt-hour Meter Product Description Operating Instructions Features and Technical Data Maintenance Instructions Diagrams and Figures Nanjing Blue Star Electrical Meter Research Institute 181 Hanzhongmen Street Nanjing 210036, China International Sales Tel: 86-25-86504148 Fax: 86-25-86601945 www.bluestarmeters.com sales@bluestarmeters.com Page 1 1/26/2005 Rev 1.0.
Blue Star C500 Static Single-phase Watt-hour Meter – IEC 61036 (1.0S) TABLE OF CONTENTS 1. Features and Applications............................................................................................................ 3 1.1 1.2 1.3 Energy Metering .............................................................................................................. 3 1.2 Data displaying ......................................................................................................... 3 1.
Blue Star C500 Static Single-phase Watt-hour Meter – IEC 61036 (1.0S) 1. Features and Applications Blue Star’s C500 watt-hour meter meets the IEC 61036 (class 1.0S) standard for energy meters. The main features of C500 include none physical adjustment components, digital signal processing, digital filters, digital error correction, digital calibration, immunity to temperature fluctuation, and excellent stability. Due to its 12 times overload multiplier, A0 can record energy usage of extreme low load.
Blue Star C500 Static Single-phase Watt-hour Meter – IEC 61036 (1.0S) There are 2 modes after data processing unit powers up: 1. Running Mode: In this mode, B500 meter can perform TOU metering, demand calculating and load monitoring, and automatically display data at given time as programmed. 2. Programming mode: A0 will switch to this mode after holding reset button for 8 seconds. In this mode, LCD will display message “PRG”.
Blue Star C500 Static Single-phase Watt-hour Meter – IEC 61036 (1.0S) 2.2 Programming B500 can be programmed (namely parameter setting) through infrared port with handheld unit. 2.2.1 Password Password is needed to program B500, reading does not need password. Password can not be modified. Password is set as “666666”, please keep it at the safety place. Page 5 1/26/2005 Rev 1.0.
Blue Star C500 Static Single-phase Watt-hour Meter – IEC 61036 (1.0S) 3. Specifications and technical data 1.1 Specifications 1.2 Technical data 1.2.1 Power supply Meter type Current (mA) Power consumption (VA) Power (W) 220V (transformer) <5 <1 <0.7 110V (transformer) <4 <0.8 <0.5 4. Use, transportation and storage conditions Same requirements as indoor meters. The number of piling layers should not exceed five in original package.
Blue Star C500 Static Single-phase Watt-hour Meter – IEC 61036 (1.
Blue Star C500 Static Single-phase Watt-hour Meter – IEC 61036 (1.0S) Appendix B: Connect Figure 3 Phase 4 Wire Direct connection Connection through current transformer Connection through current transformer and voltage transformer Page 8 1/26/2005 Rev 1.0.
Blue Star C500 Static Single-phase Watt-hour Meter – IEC 61036 (1.0S) 3 Phase 3 Wire Direct connection Connection through current transformer Connection through current transformer and voltage transformer Output Define Page 9 1/26/2005 Rev 1.0.
Blue Star C500 Static Single-phase Watt-hour Meter – IEC 61036 (1.0S) NO.1 Pulse Output NO.2 Pulse Output NO.3 Pulse Output NO.4 Pulse Output : : : : Active import energy Active export energy Reactive import energy Reactive export energy RXD : PC send data to meter TXD : Meter send data to PC Page 10 1/26/2005 Rev 1.0.