Operation Manual

Contactless access control system RP-01 2/2 VAB50202
2.4. Master position – programming and deleting
The master position has got a privileged status – reprogramming
causes deleting all PITs learned so far!!
Master position programming:
Access the learning mode. With SEL button select „position+100“ and
by pressing the SET button repeatedly select position 9xx. Press the
SET button once again and get „MASTER LEARNING“ programming
mode. Place a PIT chip and program or reprogram the master.
Master position´s content deleting:
Access the learning mode. With SEL button select „position+100“ and
by pressing the SET button repeatedly select position 9xx. Press the
SET button once again and get „MASTER LEARNING“ programming
mode. With the SEL button select „DELETE ?“ position and confirm
with SET button. This is the way to delete the content of the master
position.
In case there is no PIT programmed on the master position, just press
and hold the MOD button to access the learning mode.
2.5 Relay tie timing
To set use the MOD button. Sign „(INSERT CARD)“ displays on the
LCD when the MOD button is pressed for at least 2s. Choose the
RELAY time“ (on the LCD bottom row) by pressing the SEL button
repeatedly. Setting is made by SET button. Interval is per second 1-9s.
Confirm your choice with MOD button. To exit learning mode press and
hold MOD button. Device will go into standby mode.
2.6. Relay´s switching mode setting
Device can be set into a switching mode where every change of output
relay status is conditional on placing programmed PIT.
To set use the MOD button. Sign „(INSERT CARD)“ displays on the
LCD when the MOD button is pressed for at least 2s. Choose the
RELAY time“ (on the LCD bottom row) by pressing the SEL button
repeatedly. Setting is made with SET button when 0s value is chosen.
Confirm your choice with MOD button.To exit learning mode press and
hold MOD button. Device will go into standby mode.