Operation Manual

JS-25 COMBO PIR & glass break detector - 2 - MGD51303
For special applications other lenses can be used. Optional lenses for
long corridors and areas with small animals are supplied separately.
Pet lens is marked JS-7910. This lens prevents animals smaller then 40
cm from being detected. The working range of this lens is reduced to 7
meters. It is recommended to test this lens carefully with the animal when
installing the system, in order to prevent false alarms.
Corridor lens is marked JS-7904. The working range of this lens is 25
meters long and only 3 meters wide. It is recommended to test the detector’s
sensitivity carefully when installing it into a corridor.
Lens characteristic diagrams can be seen in documents supplied with
the lens or on the Jablotron website www.jablotron.com.
Specification
Power supply: 12 V DC ± 25%
Power consumption (LED off): max. 10 mA
Maximum consumption (LED on): max. 35 mA
Terminals size: max. 1 mm2
Tamper output: max. 60 V / 50 mA,
internal resistance max.16 Ohm
Environment- class II. – general indoor, (EN 50131-1)
Operating temperatures -10 to + 40 °C
Security level- EN 50131-1, EN 50131-2-2, CLC/TS 50 131-2-7-1 grade 2,
Mounting height: 2.5 m above floor
Initialization: typ. 1 minute
EMC EN 50130-4, EN 55022
Motion detector specification:
Detection range: 120° / 12 m (standard lens)
PIR alarm output: normally closed, max. 60V / 50 mA,
internal resistance max.30 Ohm
Glass break detector parameters:
Detection range: max. 9 m
Minimum glass dimensions: 0.6 x 0.6 m
Alarm output: normally closed, max. 60V / 50 mA,
internal resistance max.16 Ohm
JABLOTRON ALARMS a.s. hereby declares that the JS-25
is in compliance with the essential requirements and other
relevant provisions of Directive 2004/108/EC. The original of
the conformity assessment can be found on the web site
www.jablotron.com, Technical Support section.
Note: Although this product does not contain any harmful
materials we suggest you return the product to the dealer or
directly to the manufacturer after use.
Examples of the detector wiring
Example of wiring several detectors into one EOL alarm and tamper zone.
Example of wiring the JS-25 into the double EOL zone.