Operation Manual

GC-61 GSM communicator 4 / 4 MHZ51105
7. A brief list of programming instructions
8. Wiring diagram for the GC-61 – Security grade 3
Fig. 2 shows the wiring diagram for the GC-61, which is connected to a control panel. The GSM simulated line is the primary communication link with a
telephone line serving as a backup using the AUX output (see the chapter 2.15). The system checks the connection between the GC-61 and the control
panel by means of the tamper wiring. In addition the telephone line is balanced by a 10 k resistor. The resistor is attached to the PHONE terminal.
Figure. 2
Function Sequence Available setting Default setting
APN setting for GPRS
communication
GPRS
xxx,yyy,zzz,
xxx is the APN, yyy is a user name, zzz is a password Internet
Service access code PG0 xxxxxxxx xxxxxxxx is the code, 8 digits maximum 0000
ARC main telephone PG1p xxxxx
Erased
ARC back up telephone number PG2p xxxxx
p =1 for ARC1, p =2 for ARC2
xxxx = tel. number (max. 20 digits) or
a # followed by an IP address plus port which must be
specified by exactly 4x3 + 5 = 17 digits using zeros for left-
hand bit stuffing, e.g. PG11#12304506708908080
Erased
Account ID PG3p zzzz
p =1 for ARC1, p =2 for ARC2
zzzz is the account ID, 8 digits maximum
Erased
Selecting the ID number PG94 x
x=0 the ID number of the GC-61 is used for alarm system
identification.
x=1 the ID number of the attached landline communicator
is used for alarm system identification.
the ID number of the
GC-61 is used
Communication format PG4p x
p =1 for ARC1, p =2 for ARC2
x=0…Contact ID, x=1...Jablotron SMS, x=2...Jablotron
GPRS
Jablotron GPRS
ARC Report switch PG5p y
p =1 for ARC1, p =2 for ARC2
y=0... report is disabled, y=1...report is enabled
y=0
Use ARC2 as a backup of ARC1 PG62 y
y=0...two independent ARCs, y=1...ARC2 is backup for
ARC1
y=0
ARC redialling pause PG7p t p=1 ARC1, p=2 ARC2
t=1 to 9 (x 5minutes)
5 minutes
ARC connection surveillance report
frequency
07 p hh mm p=1 ARC1, p=2 ARC2
hh mm = hours minutes, 9999=24hr. after last report
24hr. after the last
report
INP input CID code setting PG-91 xxxyyzzz
xxx is a report code, yy is the number of the subsystem,
zzz is the event source
Erased
Phone number prefix setting PG-92 xx xx is the phone number prefix “+”
AUX switch control AUXON, AUXOFF
AUXON switches the AUX output on, AUXOFF switches
the AUX output off
-