Operation Manual
CR-11A Expander Module 4/4 MEI51205 CR-11A Expander Module 1/4 MEI51205
3. Central locking additional installation
Select mode number 4 on the CR-11A module. Select a duration of 0.5 sec. in car alarm setting mode.
A setting other than 0.5s will, in this case, cause damage to the actuators!
4. Arming indication by turn lights (flashers)
Select mode number 3 on the CR-11A module.
The CR-11A expander module - instructions
The CR-11A is an expander output module which provides additional functions for CA-180x, CA-32x, and
CA-1x Jablotron car alarms. The module can be used for central-locking control, immobilization, an
additional siren, electric window remote control, or for controlling appliances via SMS. It has two built-in
relays, each with a 15 Amp switch-over contact. The functions of the relays are selectable by the DIP
switches inside each CR-11A. The module receives data from the car alarm via a single wire (digital
communication). The older CR-11 module can be combined with the CR-11A. Up to four CR-11/CR-11A
units can be connected to each of the above mentioned Jablotron car alarms.
Specifications
Voltage 12V DC (10-16V DC)
Consumption stand by 5 mA
max. 300 mA (both relays on)
Relay output contacts (each) continuous 15 A
max 20 A (30 seconds)
Working temperature -40 to +85 °C
The CR-11 complies with IEC 839-10-1 and UN ECE No. 97
This product complies with the essential requirements of EU directive 89/336/EC (EMC – protection)
concerning electromagnetic compatibility when used for its intended purpose.
The original of the
conformity assessment can be found on www.jablotron.com
, Technical Support section.
Note: Although this product does not contain any harmful materials, we suggest you return the
product to the dealer or directly to the producer after usage.
Installation
Professional installation of the CR-11A is highly recommended. The module should be installed in the
passenger compartment of the car. If you drill any holes in the car, be sure to check the location of the
intended holes before drilling, to prevent damage to the car.
Disconnect the car battery before starting installation. Nobody should be inside a car equipped with airbags
while the battery is being connected or disconnected. Refer to the car owners' manual before disconnecting
the battery.
WIRING - route new wires with the pre-existing electrical harness of the car. Check each connection made
to ensure that it is secure and properly insulated. Only use a proper crimping tool to make connections. If you
use more than one CR-11A unit with a car alarm, connect all CR-11A data inputs (LINE) in parallel.
Signals on the CR-11A connector
COM1 - common contact of relay 1
NO1 - normally open contact of relay 1
NC1 - normally closed contact of relay 1
+12V - positive voltage from the car battery
GND - ground
LINE - data from the car alarm (AUX output)
COM2 - common contact of relay 2
NO2 - normally open contact of relay 2
NC1 - normally closed contact of relay 2
Setting the CR-11A relay functions
Functions of the CR-11A relays can be selected inside the unit with DIP switches marked 1 - 4. Available
options are described in the following table. Particular functions correspond to functions of the car alarm
(see car alarm manual).
Internet: www.jablotron.com
Tel.: 483 559 911
fax: 483 559 993
Pod Skalkou 33
466 01 Jablonec nad Nisou
Czech Republic