Operation Manual
- 21 - MLO51201
Other information
Time synchronization with a GSM network
Azor is equipped with the function of the automatic adjustment of the internal clock via a
GSM network. The time is saved in the event memory and sent in an informative SMS.
Warning: some GSM networks do not provide an exact time signal. In such a case Azor’s internal
clock must be set manually from a PC via A-link. If the clock is not set, no time will be stated in the
informative SMS.
Emergency unlocking of settings
If you lock Azor’s settings and forget your Service PIN, proceed as follows:
1. Unset Azor
2. Disconnect the mains adaptor from the GSM control unit.
3. Open the backup battery cover and disconnect the battery.
4. Press and hold the GSM control unit button.
5. Connect the mains adaptor (keep the button pressed).
6. As soon as all LED indicators start flashing yellow, you can release the button.
7. Connect the backup battery again and put its cover back.
8. Your original code is deleted and you will be allowed to access the Settings without
having to enter the Service PIN code.
9. When you have finished the settings, you can define a new code.
SMS message forwarding
Azor automatically forwards all received SMSes to the first phone number. An
SMS message is also sent to this number when the limit of sent SMS messages
has been exceeded.
Technical specifications
AZ-10K GSM control unit
GSM control unit power supply = 5V 2.5A max.
backup battery LI18650 = 3.7V / 2.2 Ah (usual battery lifetime is approx. 5 years)
the backup time of the control unit is 12 hours
number of users up to 10 (each may have one RFID tag and one remote control)
number of detectors up to 10
number of RFID tag readers 1
number of doorbell buttons 1
dimensions 165 x 120 x 40 mm
AZ-10D RFID tag reader
power supply 2x AAA 1.5V / 1200 mAh alkaline batteries
(battery lifetime is approx.1 year)