Operation Manual
- 15 - MLO51201
Unsetting Azor
Press the UNSET button on the RFID tag reader (A) and scan the RFID tag (B)
The green LED indicator lights up and the reader confirms its unsetting (2 beeps).
Tips and specifications
The system can also be unset via the telephone voice menu.
If you activate a detector prior to unsetting (e.g. when you open the door) a warning tone is
sounded and then AZOR waits silently for unsetting for 30 seconds. If the system is not
unset in time, an alarm is triggered.
If you press the RFID tag reader button in the unset state, a green LED indicator lights up.
If three beeps are sounded during unsetting, there has been an alarm when you were not
present.
In the event of unauthorized manipulation of some of the parts of the system in an unset
state a warning beep is sounded and an SMS tamper report is sent. The SMS report is sent
only on the first occasion of tampering with the device.
If the user has enabled SMS reporting when the system is unset, no report is sent to them if
they unset the system themselves by own remote control or RFID tag. The RFID tag
corresponding to the user (its phone number) must be used.
Alarm
When an alarm is triggered, the system informs the ARC immediately*. It concurrently
activates a siren, sends alarm SMS messages to users and subsequently calls the users.
An alarm can be cancelled by pressing the UNSET button on the reader and scanning a
RFID tag, or by using a telephone and the voice menu.
Tips and specifications
If you receive an alarm call, Azor does not call the other users. If no one receives the alarm
call, Azor tries to call all the users once more.
If you do not cancel the alarm, the siren sounds for 3 minutes and then switches off. Azor
keeps guarding.
If an identical detector triggers an alarm three times in a row (e.g. when you forget to close a
window and the wind moves a curtain in front of the detector), such a detector is bypassed and
other detectors keep guarding. A bypassed detector will be included again by unsetting.
A tamper alarm (unauthorized handling of a detector or GSM control unit) is sent just once.
Besides alarm information, Azor also sends SMS reports when it is switched off or if there is
a failure (e.g. power supply failure exceeding half an hour, low battery in a detector,
communication loss to a detector or RFID tag reader, etc.).
* If guarding by an ARC is arranged