User Manual
Programmable Control Panel 
14 
2)  Blue Keys: Keys 9-32, all are virtual keys, used in the loop function. When use the 
loop function, the ID must be set, the ID can be 1 to 99. Press “add” will add the 
button to action list. 
3)  Yellow Keys: Keys 33-36, all are virtual keys. Key 33 and 34 are for I/O control, 
which  is  not  supported  with  the  programmable control  panel.  Key  36  is  a  start 
action, if add events to this action, when the programmable control panel is power 
on, it will execute the events in this action. Key 35 is delay button, there are three 
time slots can be set. See in the picture below: 
The time is counted from the programmable control panel start. When come to time1, 
the programmable control panel will execute the events in time1. Then recount from 
time2, and then time3.   
Example: Set time1 to 5 minutes, and time2 to 3 minutes, add event1 to time1 and 
event2 to time2. When the unit starts, it will execute event1 after 5 minutes, and then 
execute event2 after 8 minutes. 