User Manual

Programmable Control Panel
14
2) Blue Keys: Keys 9-32, all are virtual keys, used in the loop function. When use the
loop function, the ID must be set, the ID can be 1 to 99. Press add will add the
button to action list.
3) Yellow Keys: Keys 33-36, all are virtual keys. Key 33 and 34 are for I/O control,
which is not supported with the programmable control panel. Key 36 is a start
action, if add events to this action, when the programmable control panel is power
on, it will execute the events in this action. Key 35 is delay button, there are three
time slots can be set. See in the picture below:
The time is counted from the programmable control panel start. When come to time1,
the programmable control panel will execute the events in time1. Then recount from
time2, and then time3.
Example: Set time1 to 5 minutes, and time2 to 3 minutes, add event1 to time1 and
event2 to time2. When the unit starts, it will execute event1 after 5 minutes, and then
execute event2 after 8 minutes.