User's Manual

J Plus, Inc
www.juniglobal.com
J Plus Proprietary and Confidential
46/88
7.2.3.3 S1AP
From the tree menu, select S1AP to move onto the S1AP setup page. Insert the number of MME and MME IP
address and click the Save button.
Figure 34: MME Setup
7.2.3.4 MR
From the tree menu, you can select MR to move on to the measurement report setup page. Choose one of trigger
quantities (RSRP, RSRQ, RSCP, Ec/No) from the list. Insert threshold value and click the Save button. Please
refer to Table 12for the detailed input parameter information.
* All units are defined reported value from TS36133 (RSRP: 9.1.4, RSRQ: 9.1.7), TS25133 (RSCP: 9.1.1.3, Ec/No: 9.1.2.3).
Menu
Intra-frequency
EUTRAN HO
Inter-frequency
EUTRAN HO
Inter-RAT
HO/Redirect/SRVCC
A1, A3, A4
A2
RSRP, range: [0, 97]
RSRQ, range: [0, 34]
Intra-Freq HO/ANR
range: [-30, 30]