Owner manual
For Your Safe Flight Page 40
Date: 05/14/09
01/01/00 ⇔
12/31/99
Hold NEXT and button 2 for 5 seconds
until you see ADJUST. Use Month,
Day, Year to adjust. Tap SAVE to
save changes. Tap NEXT to skip to
next item.
END? Yes
END? Yes
Yes exits the pilot program mode.
No reenters pilot program mode.
Adjusting the HP Constant for Rich of Peak Operation
To fine tune the %HP readout, follow this procedure airborne between
5,000 and 8,000 feet MSL.
1. Enter the pilot program mode by simultaneously holding the
STEP
and
LF buttons for five seconds.
2. Tap
STEP repeatedly until you see HP Constants. Hold both NEXT
and Button 2 until you see ROP and LOP appear in status bar. Tap
ROP
. Now HP Constant 125 should appear. Hold both NEXT and
Button 2 until you see ADJUST momentarily. Adjustment range for
the HP Constant is 45 to 180.
3. Set the MP and RPM per your POH to 70 percent power. Let
conditions stabilize.
4. Adjust the HP Constant value
PLUS or MINUS so that the %HP
reading on the display equals ‘
70 %HP’. Note: this is the percent of
maximum horsepower.
5. Hold both
NEXT and Button 2 until you see SET.
Adjusting the MAP
This procedure allows you to adjust the MAP to the altimeter setting at a
sea level airport. NOTE: If airport is not at sea level, use the
correction table to derive corrected sea level altimeter setting).
1. Enter the pilot program mode by simultaneously holding the
STEP
and
LF buttons for five seconds.
2. Tap
NEXT repeatedly until you see Lft MAP +0.0. Then hold both
the
NEXT and Button 2 until you see ADJUST momentarily.