For Your Safe Flight Page 5
Section 2 - Interpreting Data
Operation for each Phase of Flight
(worth adding to your run-up checklist.)
Engine Run-Up
Suggested setup:
Set engine to run-up RPM
Normalize view
Manual mode
Verify:
uniform rise of about 50°F in all EGTs in single
magneto operation.
uniform rise of EGTs with application of the
mixture control.
Be alert for:
unusually low voltage (see AFMS)
cold OIL and normal oil pressure
abnormally high CHT
large drop in EGT on one cylinder in single
magneto operationmay be fouled spark plug.