User guide

For Your Safe Flight Page 19
Manual Mode
To activate Manual Mode, just tap the STEP button. Use the Manual
mode when you want to lock on one specific measurement such as shock
cooling during descent, or your hottest CHT during climbs. To select the
desired parameter, tap the STEP button until it appears. To return to the
Automatic mode, tap the LF button and then tap the STEP button. You
may completely disable the Automatic mode by setting zero for ‘Auto
Scan Rate 4’. See Pilot Programming.
Scan Sequence Example
Measurement EXAMPLE COMMENTS
EGT, CHT EGT 1354 CHT 335
Square indicates the cylinder being
viewed
TIT 1370 TIT
Turbine Inlet Temperature # 1
Shock Cooling -30 CLD
Square indicates fastest cooling
cylinder
Compressor Discharge
Temperature
300 CDT Temperature into intercooler
Induction Air Temperature 125 IAT
Temperature out of the intercooler
Carburetor Temperature -22 CRB
(Not available when CDT is
installed)
Difference between
hottest and coldest EGT
80 DIF
Square indicates most widely
deviating cylinder
Fuel Remaining
Calculated
37.2 REM
In gallons, liters, pounds or
kilograms
Fuel required to next GPS
WPT or Destination
25.9 REQ
Present with GPS interface, valid
signal and way point
Fuel Reserve at next GPS
WPT or Destination
Calculated
11.3 RES
Present with GPS interface, valid
signal and way point
Nautical Miles per Gal 13.0 MPG
Present with GPS interface and
valid signal. MPK, MPL, MPP for
dif units
Time to Empty
Calculated
02:45 H:M
Hours: minutes calculated
remaining at current fuel burn.
Total Fuel Used 38 USD
Since last refueling or trip total.