Installation Manual User guide
J.P.Instruments
Fuel Flow Installation Manual
Report # 503
for EGT-701 with Fuel Flow Option Page 7 of 14
Rev B : Date 03/14/97
9… Pilot Programmable Modes: (
excerpt from STC 2586NM)
See JPI Installation Manual For EGT-701, No 103 Page 8 for more information.
RS232/422 Input Ports (EGT-701(),with Fuel Flow option Only!:
Single Line Receive Method: RS-232C, RS423, or 5 Volt Serial.
Dual Line Receive Method: RS-422 or RS-485.
Protocol: 1 Start bit, 8 Data bits, 1 Stop bit.
Baud Rate: L 1 = 9600, L 2 = 1200
Format: Moving Map Output: L 1 = King KIN-88, L 2 = Northstar
RS232 Output Port
Transmit Method: RS-232 Single Line.
Protocol: 1 Start bit, 8 Data bits, 1 Stop bit.
Baud Rate: 9600
Transmit Format: King KIN-88.
Fuel Flow Transducer, Standard (FXT-201) Fuel Flow Transducer, Gravity Only (FXT-231):
Range: 0.6 to 60 GPH Range: 3 to 90 GPH
Linearity: %1 (8 to 60 GPH) Linearity: %1 (8 to 60 GPH)
K Factor Approx. 29,000 K Factor: Approx. 19500
Pressure Drop: 1.2 PSI at 30 GPH
4.8 PSI at 60 GPH
Pressure Drop: .31 PSI at 30 GPH
2.8 PSI at 90 GPH
Working Press: 200 PSI Working Press: 200 PSI
Min. Burst Press: 2000 PSI Min. Burst Press: 2000 PSI
Temp. Range: -65'C to 125'C Temp. Range: -65'C to 125'C
Fuel Ports: 1/4" Female NPT Fuel Ports: 1/4" Female NPT