Instruction Manual
For 275 ST Model
For 375 ST Model
Fasten the Transfer Tube to the Talc Holding Container us-
ing the supplied bracket. Two 3/8” clearance holes will need
to be drilled into the shell assembly to install the bracket.
Use (2) 3/8” x 1” hex bolts and nut to fasten the bracket to
the shell assembly. Install the 3/8” x 3” U-bolt. Use (2) 3/8”
serrated ange hex nuts and (2) 3/8” lock nuts to fasten the
U-bolt to the bracket. Tighten hardware once installed.
Step 5.
Step 5.
Fasten the Transfer Tube to the Talc Holding Container using
the supplied bracket. Start installing the bracket by removing
the two bolts shown in the image above. Now fasten the bracket
to the door with the two nuts that were just removed. Install
the 3/8” x 3” U-bolt. Use (2) 3/8” serrated ange hex nuts and
(2) 3/8” lock nuts to fasten the U-bolt to the bracket. Tighten
hardware once installed.