Instruction Manual

Step 3.
On the Hydraulic Spool Valve remove the “Return” hose on the valve body for the conveyor. Install the 1/2” by
17” hydraulic hose from the valve body to the Talc Applicator Control Valve. Connect hose to #3 on the talc
applicator valve body. Tighten all ttings once installed.
Step 4.
Install the last 1/2” x 17” hose. is hose connects to # 4 on the Talc Applicator Valve Body and to the Conveyor
Return Hose, which was removed from the Hydraulic Valve Body in step 3. Tighten all ttings once installed.
Remove Conveyor Return
Hose and 90 Deg. Fitting.
17” Hydraulic
Hose
17” Hydraulic
Hose
Conveyor
Return Hose
#3
#4
Note: 1/4” Hoses will be installed in step 8.