Product Manual A
Maintenance Instructions
• Disconnect power before cleaning or maintaining your fan in order
to prevent serious injury or death.
• Service and repair of fan should only be completed by a qualified
technician.
• For maximum efficiency and fan life, keep the following free from
dirt and dust: blades, motor and guard.
• The totally enclosed air over motor has sealed ball bearings and
does not require additional oil/lubrication.
DISCONNECT POWER
BEFORE INSTALLING OR SERVICING.
ALL ELECTRICAL WORK SHOULD BE COMPLETED BY
QUALIFIED PERSONNEL AND MEET NATIONAL (NEC),
REGIONAL AND LOCAL ELECTRIC CODES.
! !
Connecting Power To The Unit
• Install manual disconnect switch inside
building adjacent to fan.
• Use either rubber covered or flexible water-
tight conduit and stranded wire.
• Route wire to motor with drip loop and
secure. Drip loop will drain accumulated
moisture away from the motor.
• Configure internal wires to match supply
voltage and wire according to motor
nameplate. Test to verify correct rotation.
• Shut off manual disconnect for remainder
of install. Only permit power to unit when
shutter and guard are fully installed to
prevent injury.
6
Using a #2 square drive bit reinstall the rear guard and clips that were
removed in Step 3.
7
Using a minimum of 12 fasteners suitable to your structure secure the unit
in the opening as shown below, 3 fasteners per side.
5
IS276-17I
J&D Manufacturing • 6200 Hwy 12 • Eau Claire, WI 54701 • 1-800-998-2398 • www.jdmfg.com