Datasheet

MCD162-08io1
0 100 200 300 400
0
400
800
1200
1600
t[s]
10
-3
10
-2
10
-1
10
0
10
1
10
2
0.0
0.1
0.2
0.3
Z
thJC
[K/W]
I
RMS
[A]
P
tot
[W]
0 25 50 75 100 125 150
T
a
[°C]
10
-3
10
-2
10
-1
10
0
10
1
10
2
0.00
0.08
0.16
0.24
Z
thJK
[K/W]
t[s]
Fig. 8 Three phase AC-controller: Power dissipation versus
RMS output current and ambient temperature
Fig. 9 Transient thermal impedance junction to case (per thyristor/diode)
Fi
g
. 10 Transient thermal im
p
edance
j
unction to heatsink
(
p
er th
y
ristor/diode
R
thJC
for various conduction angles d:
d R
thJC
[K/W]
DC 0.155
180° 0.167
120° 0.176
60° 0.197
30° 0.227
Constants for Z
thJC
calculation:
i R
thi
[K/W] t
i
[s]
1 0.0072 0.001
2 0.0188 0.080
3 0.1290 0.200
R
thJK
for various conduction angles d:
d R
thJK
[K/W]
DC 0.225
180° 0.237
120° 0.246
60° 0.267
30° 0.297
Constants for Z
thJK
calculation:
i R
thi
[K/W] t
i
[s]
1 0.0072 0.001
2 0.0188 0.080
3 0.1290 0.200
4 0.0700 1.000
0.15
0.1
0.08
R
thKA
K/W
0.2
0.03
0.04
0.06
0.3
Circuit
W3
3xMCC162 or
3xMCD162
DC
180°
120°
60°
30°
DC
180°
120°
60°
30°
Rectifier
IXYS reserves the right to change limits, conditions and dimensions.
20131121aData according to IEC 60747and per semiconductor unless otherwise specified
© 2013 IXYS all rights reserved