Datasheet
PS2601
www.clare.com
3
R10
PERFORMANCE DATA*
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifi cations, please
contact our application department.
-40
1.2
1.0
0.8
0.6
0.4
0.2
05585
0
Ambient Temperature (ºC)
PS2601
Load Current, Free Air
R
θJA
=60ºC/W
Load Current (A
rms
)
-40
4
3
2
1
05585
0
PS2601
Load Current, Heat Sink
Ambient Temperature (ºC)
Load Current (A
rms
)
PS with Thermal Clip attached
to 3ºC/W heat sink
PS with Thermal Clip freestanding
20
15
10
5
0
16 50 100
25
PS2601
Max. Surge Current (Non-Repetitive)
Pulse Duration (ms)
Peak Surge Current (A)
NOTE: Values apply to
T
J
=50ºC before Surge
0
1.3
1.2
1.1
1.0
10 25 40 55 70 85
0.9
Forward Voltage (V)
Ambient Temperature (ºC)
PS2601
Typical Forward Voltage vs. Temperature
Critical Rate of Rise (V/µs)
0
800
600
400
200
1200
1000
25 50 85
1400
0
Ambient Temperature (ºC)
PS2601
Typical dV/dt vs. Temperature
Vo
63%
10%
RC
PS2601
dV/dt Method
In accordance with
EIA/NARM Standards
RS-443 for Solid State Relays
Vo = 300V
dV
dt
0.63 x 300V
RC
RC
189
==