Datasheet
www.clare.com
PLA140
Rev. 5
Electrical Characteristics
Absolute Maximum Ratings are stress ratings. Stresses
in excess of these ratings can cause permanent damage
to the device. Functional operation of the device at these
or any other conditions beyond those indicated in the
operational sections of this data sheet is not implied.
Exposure of the device to the absolute maximum ratings
for an extended period may degrade the device and effect
its reliability.
Absolute Maximum Ratings (@ 25˚ C)
2
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics @ 25°C
Load Voltage (Peak) - V
L
- - 400 V
Load Current (Continuous)
AC/DC Configuration - I
L
- - 250 mA
DC Configuration - I
L
- - 350 mA
Peak Load Current 10ms I
L
- - 500 mA
On-Resistance
AC/DC Configuration I
L
=250mA R
ON
-6 8 Ω
DC Configuration I
L
=350mA R
ON
-2 3 Ω
Off-State Leakage Current V
L
=400V I
LEAK
-- 1 µA
Switching Speeds
Turn-On I
F
=5mA, V
L
=10V T
ON
- - 3.0 ms
Turn-Off I
F
=5mA, V
L
=10V T
OFF
- - 1.0 ms
Output Capacitance 50V; f=1MHz C
OUT
-65 - pF
Input Characteristics @ 25°C
Input Control Current I
L
=250mA I
F
5- 50mA
Input Dropout Current - I
F
0.4 0.7 - mA
Input Voltage Drop I
F
=5mA V
F
0.9 1.2 1.4 V
Reverse Input Voltage - V
R
-- 5 V
Reverse Input Current V
R
=5V I
R
- - 10 µA
Common Characteristics @ 25°C
Input to Output Capacitance - C
I/O
-3 - pF
Input to Output Isolation - V
I/O
3750 - - V
RMS
Parameter Min Typ Max Units
Input Power Dissipation - - 150
1
mW
Input Control Current - - 50 mA
Peak (10ms) - - 1 A
Reverse Input Voltage - - 5 V
Total Power Dissipation - - 800
2
mW
Isolation Voltage
Input to Output 3750 - - V
RMS
Operational Temperature -40 - +85 °C
Storage Temperature -40 - +125 °C
Soldering Temperature
DIP Package - - +260 °C
Surface Mount Package - - +220 °C
(10 Seconds Max.)
1
Derate Linearly 1.33 mw/˚C
2
Derate Linearly 6.67 mw/˚C