Datasheet

© 2004 IXYS All rights reserved
2 - 4
419
MCC 26
MCD 26
IXYS reserves the right to change limits, test conditions and dimensions
Symbol Conditions Characteristic Values
I
RRM
, I
DRM
T
VJ
= T
VJM
; V
R
= V
RRM
; V
D
= V
DRM
3mA
V
T
, V
F
I
T
, I
F
= 80 A; T
VJ
= 25°C 1.64 V
V
T0
For power-loss calculations only (T
VJ
= 125°C) 0.85 V
r
T
11.0 m
V
GT
V
D
= 6 V; T
VJ
= 25°C 1.5 V
T
VJ
= -40°C 1.6 V
I
GT
V
D
= 6 V; T
VJ
= 25°C 100 mA
T
VJ
= -40°C 200 mA
V
GD
T
VJ
= T
VJM
;V
D
=
2
/
3
V
DRM
0.2 V
I
GD
10 mA
I
L
T
VJ
= 25°C; t
P
= 10 µs; V
D
= 6 V 450 mA
I
G
= 0.45 A; di
G
/dt = 0.45 A/µs
I
H
T
VJ
= 25°C; V
D
= 6 V; R
GK
= 200 mA
t
gd
T
VJ
= 25°C; V
D
= 1/2 V
DRM
s
I
G
= 0.45 A; di
G
/dt = 0.45 A/µs
t
q
T
VJ
= T
VJM
; I
T
= 20 A, t
P
= 200 µs; -di/dt = 10 A/µs typ. 150 µs
V
R
= 100 V; dv/dt = 20 V/µs; V
D
= 2/3 V
DRM
Q
S
T
VJ
= T
VJM
; I
T
, I
F
= 25 A, -di/dt = 0.64 A/µs 50 µC
I
RM
6A
R
thJC
per thyristor/diode; DC current 0.88 K/W
per module other values 0.44 K/W
R
thJK
per thyristor/diode; DC current see Fig. 8/9 1.08 K/W
per module 0.54 K/W
d
S
Creepage distance on surface 12.7 mm
d
A
Strike distance through air 9.6 mm
a Maximum allowable acceleration 50 m/s
2
Optional accessories for module-type MCC 26 version 1 B
Keyed gate/cathode twin plugs with wire length = 350 mm, gate = yellow, cathode
= red
Type ZY 200L (L = Left for pin pair 4/5) UL 758, style 1385,
Type ZY 200R (R = right for pin pair 6/7) CSA class 5851, guide 460-1-1
Dimensions in mm (1 mm = 0.0394")
MCC Version 1 B MCC Version 8 B MCD Version 8 B
10 100 1000
1
10
100
1000
10
0
10
1
10
2
10
3
10
4
0.1
1
10
I
G
V
G
mA
mA
I
G
1: I
GT
, T
VJ
= 125°C
2: I
GT
, T
VJ
= 25°C
3: I
GT
, T
VJ
= -40°C
µs
t
gd
V
4: P
GAV
= 0.5 W
5: P
GM
= 5 W
6: P
GM
= 10 W
I
GD
, T
VJ
= 125°C
3
4
2
1
5
6
Limit
typ.
T
VJ
= 25°C
Fig. 1 Gate trigger characteristics
Fig. 2 Gate trigger delay time