Datasheet
IXYS Reserves the Right to Change Limits, Test Conditions, and Dimensions.
IXYH40N120C3D1
Fig. 7. Transconductance
0
4
8
12
16
20
24
28
0 102030405060708090
I
C
- Amperes
g
f s
-
Siemens
T
J
= - 40ºC
25ºC
150ºC
Fig. 10. Reverse-Bias Safe Operating Area
0
10
20
30
40
50
60
70
80
90
200 300 400 500 600 700 800 900 1000 1100 1200 1300
V
CE
- Volts
I
C
- Amperes
T
J
= 150ºC
R
G
= 10
Ω
dv / dt < 10V / ns
Fig. 11. Maximum Transient Thermal Impedance
0.001
0.01
0.1
1
0.00001 0.0001 0.001 0.01 0.1 1
Pulse W idth - Second
Z
(th)JC
- ºC / W
Fig. 8. Gate Charge
0
2
4
6
8
10
12
14
16
0 102030405060708090
Q
G
- NanoCoulombs
V
GE
- Volts
V
CE
= 600V
I
C
= 40A
I
G
= 10mA
Fig. 9. Capacitance
10
100
1,000
10,000
0 5 10 15 20 25 30 35 40
V
CE
- Volts
Capacitance - PicoFarads
f
= 1 MHz
C
ies
C
oes
C
res