Datasheet
IXYS Reserves the Right to Change Limits, Test Conditions, and Dimensions.
IXGN200N60B3
Fig. 11. Maximum Transient Thermal Impedance
0.001
0.010
0.100
1.000
0.0001 0.001 0.01 0.1 1 10
Pulse Width - Seconds
Z
(th)JC
- ºC / W
Fig. 7. Transconductance
0
40
80
120
160
200
240
0 20 40 60 80 100 120 140 160 180 200
I
C
- Amperes
g
f s
-
Siemens
T
J
= - 40ºC
25ºC
125ºC
Fig. 10. Reverse-Bias Safe Operating Area
0
50
100
150
200
250
300
350
100 200 300 400 500 600
V
CE
- Volts
I
C
- Amperes
T
J
= 125ºC
R
G
= 1
dv / dt < 10V / ns
Fig. 8. Gate Charge
0
2
4
6
8
10
12
14
16
0 100 200 300 400 500 600 700 800
Q
G
- NanoCoulombs
V
GE
- Volts
V
CE
= 300V
I
C
= 100A
I
G
= 10mA
Fig. 9. Capacitance
10
100
1,000
10,000
100,000
0 5 10 15 20 25 30 35 40
V
CE
- Volts
Capacitance - PicoFarads
f
= 1 MHz
C
ies
C
oes
C