Datasheet
© 2000 IXYS All rights reserved
2 - 2
DSEI 8, 600 V
Fig. 1 Forward current Fig. 2 Recovery charge versus -di
F
/dt. Fig. 3 Peak reverse current versus
versus voltage drop. -di
F
/dt.
Fig. 4 Dynamic parameters versus Fig. 5 Recovery time versus -di
F
/dt. Fig. 6 Peak forward voltage
junction temperature. versus di
F
/dt.
Fig. 7 Transient thermal impedance junction to case.
Dimensions TO-220 AC
Dim. Millimeter Inches
Min. Max. Min. Max.
A 12.70 14.73 0.500 0.580
B 14.23 16.51 0.560 0.650
C 9.66 10.66 0.380 0.420
D 3.54 4.08 0.139 0.161
E 5.85 6.85 0.230 0.420
F 2.54 3.42 0.100 0.135
G 1.15 1.77 0.045 0.070
H - 6.35 - 0.250
J 0.64 0.89 0.025 0.035
K 4.83 5.33 0.190 0.210
L 3.56 4.82 0.140 0.190
M 0.38 0.56 0.015 0.022
N 2.04 2.49 0.080 0.115
Q 0.64 1.39 0.025 0.055
Dimension TO-263 AA see DSEI 19
033