Datasheet

© 2000 IXYS All rights reserved
2 - 2
DSEI 20, 1200V
Fig. 1 Forward current Fig. 2 Recovery charge versus -di
F
/dt. Fig. 3 Peak reverse current versus
versus voltage drop. -di
F
/dt.
Fig. 7 Transient thermal impedance junction to case.
Dim. Millimeter Inches
Min. Max. Min. Max.
A 12.70 14.73 0.500 0.580
B 14.23 16.51 0.560 0.650
C 9.66 10.66 0.380 0.420
D 3.54 4.08 0.139 0.161
E 5.85 6.85 0.230 0.420
F 2.54 3.42 0.100 0.135
G 1.15 1.77 0.045 0.070
H - 6.35 - 0.250
J 0.64 0.89 0.025 0.035
K 4.83 5.33 0.190 0.210
L 3.56 4.82 0.140 0.190
M 0.38 0.56 0.015 0.022
N 2.04 2.49 0.080 0.115
Q 0.64 1.39 0.025 0.055
Dimensions
1 10 100 1000
0
1
2
3
4
5
6
0 200 400 600
0
10
20
30
40
50
0 200 400 600
0.1
0.3
0.5
0.7
0.9
0.2
0.4
0.6
0.8
1.0
A/ s
µs
0 200 400 600
0
10
20
30
40
50
60
T
VJ
=125°C
I
F
=30A
-di
F
/dt
t
fr
V
FR
t
fr
ns
0
200
400
600
800
1000
1200
V
V
FR
-di
F
/dt
t
rr
typ.
max.
0 40 80 120 160
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
Q
R
I
RM
°C
T
VJ
A
max.
typ.
-di
F
/dt
I
RM
-di
F
/dt
Q
r
01234
0
10
20
30
40
50
60
70
V
V
F
I
F
T
VJ
=150°C
T
VJ
=100°C
T
VJ
= 25°C
A
I
F
=15A
I
F
=30A
I
F
=60A
I
F
=30A
V
R
= 540V
T
VJ
=100°C
max.
typ.
I
F
=15A
I
F
=30A
I
F
=60A
I
F
=30A
T
VJ
=100°C
V
R
= 540V
V
R
=540V
T
VJ
=100°C
I
F
=15A
I
F
=30A
I
F
=60A
I
F
=30A
A/
s
A/
s
A/
s
µC
K
f
Fig. 4 Dynamic parameters versus Fig. 5 Recovery time versus -di
F
/dt. Fig. 6 Peak forward voltage
junction temperature. versus di
F
/dt.