Data Sheet

© 2002 IXYS All rights reserved
2 - 3
CS 20
Symbol Test Conditions Characteristic Values
I
R
, I
D
T
VJ
= T
VJM
; V
R
= V
RRM
; V
D
= V
DRM
£ 2 mA
V
T
I
T
= 25 A; T
VJ
= 25°C £ 2.1 V
V
T0
For power-loss calculations only (T
VJ
= 125°C) 1.1 V
r
T
40 mW
V
GT
V
D
= 6 V; T
VJ
= 25°C £ 1.0 V
T
VJ
= -40°C £ 1.2 V
I
GT
V
D
= 6 V; T
VJ
= 25°C £ 65 mA
T
VJ
= -40°C £ 80 mA
T
VJ
= 125°C £ 50 mA
V
GD
T
VJ
= T
VJM
;V
D
= 2/3 V
DRM
£ 0.2 V
I
GD
£ 5mA
I
L
T
VJ
= 25°C; t
P
= 10 ms £ 150 mA
I
G
= 0.3 A; di
G
/dt = 0.3 A/ms
I
H
T
VJ
= 25°C; V
D
= 6 V; R
GK
= ¥ £ 100 mA
t
gd
T
VJ
= 25°C; V
D
= 1/2 V
DRM
£ 2 ms
I
G
= 0.3 A; di
G
/dt = 0.3 A/ms
R
thJC
DC current 0.62 K/W
R
thJH
DC current 0.82 K/W
a Max. acceleration, 50 Hz 50 m/s
2
Fig. 1 Gate trigger range
Fig. 2 Gate controlled delay time t
gd
10 100 1000
1
10
100
1000
µs
t
gd
I
G
1 10 100 1000 10000
0.1
1
10
I
G
V
G
mA
V
4
2
1
5
6
mA
typ.
Limit
3
T
VJ
= 25°C
I
GD
, T
VJ
=125°C
4: P
GAV
= 0.5 W
5: P
GM
= 1 W
6: P
GM
= 10 W
1: I
GT
, T
VJ
= 125°C
2: I
GT
, T
VJ
= 25°C
3: I
GT
, T
VJ
= -40°C
TO-247 AD and ISOPLUS 247
TM
Dim. Millimeter Inches
Min. Max. Min. Max.
A 19.81 20.32 0.780 0.800
B 20.80 21.46 0.819 0.845
C 15.75 16.26 0.610 0.640
D* 3.55 3.65 0.140 0.144
E 4.32 5.49 0.170 0.216
F 5.4 6.2 0.212 0.244
G 1.65 2.13 0.065 0.084
H - 4.5 - 0.177
J 1.0 1.4 0.040 0.055
K 10.8 11.0 0.426 0.433
L 4.7 5.3 0.185 0.209
M 0.4 0.8 0.016 0.031
N 1.5 2.49 0.087 0.102
* ISOPLUS 247
TM
without hole