Data Sheet
© 2007 IXYS All rights reserved
2 - 3
20071212a
CS 19
IXYS reserves the right to change limits, test conditions and dimensions.
Symbol Conditions Characteristic Values
typ. max.
I
R
, I
D
V
R
= V
RRM
; V
D
= V
DRM
; T
VJ
= T
VJM
5 mA
V
T
I
T
= 20 A; T
VJ
= 25°C 1.6 V
V
T0
r
T
For power-loss calculations only
T
VJ
= 125°C
0.85
27
V
mW
V
GT
I
GT
V
D
= 6 V; T
VJ
= 25°C
T
VJ
= -40°C
V
D
= 6 V; T
VJ
= 25°C
T
VJ
= -40°C
1.5
2.5
28
50
V
V
mA
mA
V
GD
I
GD
V
D
=
2
/
3
V
DRM
; T
VJ
= T
VJM
0.2
3
V
mA
I
L
t
p
= 10 µs; T
VJ
= 25°C
I
G
= 0.1 A; di
G
/dt = 0.1 A/µs
75 mA
I
H
V
D
= 6 V; R
GK
= ∞; T
VJ
= 25°C 50 mA
t
gd
V
D
= ½ V
DRM;
T
VJ
= 25°C
I
G
= 0.1 A; di
G
/dt = 0.1 A/µs
2 µs
R
thJC
R
thJH
DC current
DC current 0.25
1.0
K/W
K/W
a
Max. acceleration; 50 Hz 50 m/s
2
G
C
D
F
B
H
A
J
K
L
Q
R
E
N
M
TO-220 AB Dimensions (1 mm = 0.0394")
TO-263 AA
Dim. Millimeter Inches
Min. Max. Min. Max.
A 12.70 13.97 0.500 0.550
B 14.73 16.00 0.580 0.630
C 9.91 10.66 0.390 0.420
D 3.54 4.08 0.139 0.161
E 5.85 6.85 0.230 0.270
F 2.54 3.18 0.100 0.125
G 1.15 1.65 0.045 0.065
H 2.79 5.84 0.110 0.230
J 0.64 1.01 0.025 0.040
K 2.54 BSC 0.100 BSC
M 4.32 4.82 0.170 0.190
N 1.14 1.39 0.045 0.055
Q 0.35 0.56 0.014 0.022
R 2.29 2.79 0.090 0.110