Manual
Table Of Contents
Installation 9 (22)
5 Installation
5.1 Installing the Software
For the operation of the interface a driver is needed.
The USB-to-CAN
FD
is only supported by VCI V4 or newer.
Windows
► Install the VCI driver (see Installation Guide VCI Driver).
Linux and Real-Time Operating Systems
► Observe information about supported operating systems and interfaces on www.ixxat.com.
5.2 Installing the Hardware
5.2.1 Connecting USB
Malfunction caused by extension cable!
According to the USB specification connect the interface directly or via an active USB hub
to the computer. Do not use an extension cable.
Insufficient power supply!
Connect the interface directly to the computer or to self-powered hubs to ensure
sufficient power supply.
The shield of the USB cable is connected to ground using a 100 nF capacitor. The shield of the
CAN connector is connected to CAN ground via a 1 MΩ resistor and a 10 nF capacitor. The shields
of the CAN connectors of the variant automotive are connected directly together.
USB-to-CAN
FD
Compact/Automotive
Connector:
• USB cable with plug type A
• Assignment corresponds to USB 2.0 standard.
► Make sure that the VCI driver is installed.
► Plug the USB connector in the USB port of the computer.
→ Windows automatically finds and installs the hardware.
→ USB LED is green.
USB interface supports hot plug!
It is possible to plug or unplug the device during operation.
USB-to-CAN
FD
User Manual