Instructions

Configuration 18 (30)
6.4 Bridge Configuration
In the Bridge configuration each device can be configured differently, but all devices must be
configured in one configuration file. The configuration can be set for one device and then
downloaded to the other devices (Master, Slave 1 to 3). In the Local CAN Bridge mode only one
device is connected and has to be configured.
Configuration fails, if the individual devices of a CAN-Ethernet-CAN Bridge are configured
from different configuration files! Observe that for the configuration of a CAN-Ethernet-
CAN Bridge each device must be configured with the same configuration file. If the
configuration is changed, the new configuration file has to be downloaded again to all
devices.
Exclusively one master device is allowed in the Bridge mode.
Fig. 12 CAN-Gateway Configurator CAN@net NT 420
Connect the Master device to the host computer (see Connecting Possibilities, p. 12).
Make sure, that the basic configurations are set (see Basic Configuration, p. 13).
Make sure, that the desired operational mode is selected in drop-down list (2).
In configuration tree (1) select CAN@net General.
If CAN-Ethernet-CAN Bridge is selected, enter the IP addresses of the Master device and of
all connected Slave devices.
Configure the baud rate settings for the CAN ports of the Master device and of all Slave
devices and the mapping table (for more information see User Manual CAN-Gateway
Configurator on www.ixxat.com).
For descriptions of the further configuration possibilities see User Manual CAN-Gateway
Configurator.
After the configuration click button Write to (5) to write the configuration to device.
Click button Save (3) or Save as (4) to save the configuration.
5
1
2 3
4
CAN@net NT User Manual
4.01.0332.20000 1.6 en-US