Configuration 15 (30)
► Select the desired device in the drop-down list Target device.
► If necessary define a new IP address.
► Make sure that the IP address is in the range of the network in which the device is
integrated.
► Define the network settings.
► Enter password (default: IXXAT) in field Device password.
► To write the new IP configuration to the target device click button Save.
► Connect the device in CAN-Gateway Configurator (see Connecting the Device in CAN-
Gateway Configurator, p. 15).
6.2.3 Connecting the Device in CAN-Gateway Configurator
Fig. 10 CAN-Gateway Configurator
► Connect a device to the host computer (see Connecting Possibilities, p. 12).
► Make sure, that the initial settings are configured (see Prerequisites and Initial Settings, p.
13).
► If the device is connected via a router, enter the IP address (see Default Network Settings, p.
24) in combo box Target Device (3).
or
If the device is connected via USB or Ethernet in a local network, click button Scan (2) and
select the device in use in combo box Target Device (3).
► Click button Connect (4) to connect the selected device.
► For ASCII Gateway and VCI Interface mode make sure that the IP address is in the range of
the network in which the device is integrated (see Changing the IP Address, p. 16).
► For CAN-Ethernet-CAN bridge make sure that the IP addresses of all devices of the bridge
are in the same IP range (see Changing the IP Address, p. 16).
► To create a new project file, click button New (1).
or
To change an existing configuration, click button Read from (5) and save the configuration.
► Configure the device in the selected mode (see ASCII Gateway Configuration, p. 17, Bridge
Configuration, p. 18 or VCI Interface Configuration, p. 19).
1 2
3 4
5
CAN@net NT User Manual