Instructions

Configuration 13 (30)
6.2 Basic Configuration
CAN@net NT 200 and CAN@net NT 420 can not be combined. For CAN-Ethernet-CAN
Bridges use either NT 200 devices or NT 420 devices.
Fig. 8 CAN-Gateway Configurator
1
Information about target device (STS reflects Power LED of device)
2
Drop-down list Select device type
3
Drop-down list Select device version
4
Drop-down list Select operational mode
5 Button New
6 Button Open
7 Button Save
8 Button Save as
9
Button Verify
10 Button Scan
11
Combo box Target device
12 Button Connect
13
Button Write to
14
Button Read from
15
Terminal window
6.2.1 Prerequisites and Initial Settings
To use all features the latest firmware versions of the CAN-Gateway Configurator and the
CAN@net NT must be installed.
Make sure, that the latest VCI driver is installed.
Make sure, that the device is installed correctly (see Installing the Hardware, p. 8).
Connect a device to the host computer (see Connecting Possibilities, p. 12).
Make sure, that the latest firmware is on the device (see Checking and Updating the
Firmware, p. 10).
Make sure, that the latest CAN-Gateway Configurator is installed (check within support area
on www.ixxat.com).
Start the CAN-Gateway Configurator.
To identify the connected devices and the firmware version open menu scan Scan and
select All Ixxat devices.
Connected devices and firmware version of the devices are shown.
Devices that are connected via a router are not found. IP address and device firmware
version must be known.
Devices with an unknown or invalid IP address are not found (for more information see
Scanning for Devices with Unknown IP Addresses, p. 14).
3
4 5 6 7 8
9
10
1 1 12
2
1
13
14
15
CAN@net NT User Manual