Manual

Safety Instructions 5 (22)
2 Safety Instructions
2.1 Information on EMC
Risk of interference to radio and television if used in office or home environment! The
product is a class B device.
Use exclusively included accessories or HMS accessories that are intended for use with
the device. Use exclusively shielded cables.
Make sure that the shield of the interface is connected with the device plug and the plug
on the other side.
2.2 General Safety Instructions
Protect product from moisture and humidity.
Protect product from too high or too low temperature (see Technical Data, p. 15).
Protect product from fire.
Do not paint the product.
Do not modify or disassemble the product. Service must be carried out by HMS Industrial
Networks.
Store products in dry and dust-free place.
2.3 Intended Use
The interfaces are used to connect computer systems to CAN and LIN networks. The USB-to-
CAN
V2
Embedded is intended for installation in computer systems with closed housing. The USB-
to-CAN
V2
Compact, Professional and Automotive are intended for the connection to a computer
via the USB interface.
Product versions that are not galvanically isolated are only allowed to operate inside buildings in
CAN networks of maximally 30 m length (order number 1.01.0281.11001).
3 Scope of Delivery
Included in the scope of delivery:
USB-to-CAN
V2
interface
only version professional and automotive: 2 x RJ45 to D-Sub 9 adapter cable
Installation Guide VCI Driver
User Manual USB-to-CAN
V2
The following equipment can be ordered separately:
CAN bus termination
RJ45 to D-Sub 9 adapter cable
Drivers for Windows, Linux and real-time operating systems, including programming examples,
CAN bus monitor and software design guides are available on www.ixxat.com/support.
USB-to-CAN
V2
User Manual
4.01.0280.20000 2.7 en-US