Data Sheet
FEATURES AND BENEFITS
CONTENTS OF DELIVERY
TECHNICAL SPECIFICATIONS
CAN-CR220
ISO 11898-2 CAN repeater
with 4 kV galvanic isolation
The CAN-CR220 is used for the galvanic isolation of two segments of a CAN network and offers a
very high galvanic isolation of 4 kV, allowing it be utilized in medical applications. One special
feature of the Repeater is the automatic recognition and separation of a defective segment from
the rest of the network so that the remaining network can continue working. After elimination of
the defect, the segment is switched into the network again.
The galvanic isolation isolates the CAN segments from each other as well as from the power
supply.
The CAN-CR220 is tested according DIN/EN 50178 (DIN VDE 0160: 1988-05 and DIN VDE
0160/A1: 1989-04).
Line protection up to 4 kV
DIN/EN 50178 (DIN VDE 0160: 1988-05 and DIN VDE 0160/A1: 1989-04)
Cost savings due to simple wiring
Increased system reliability
Almost no influence on real-time behavior
CAN-CR220
Quick reference
Display Transmit and defective segment (two duo LEDs), Power (one LED)
CAN bus interface ISO 11898-2 with CAN choke. Two Sub-D9 connectors. CAN termination resistors are integrated
(switchable).
Baudrate Up to 1 Mbit/s
Delay 200 ns (corresponds ~40 m (~120ft.) bus length)
Power supply 9-32 V DC, 1.5 W typ., through terminals
Galvanic isolation CAN 1, CAN 2 and power supply are galvanic isolated against each other.
Isolation voltage 1.01.0067.44400
- 2.0 kV AC / 1 min
- 3.2 kV DC / 1 min