Manual

Table Of Contents
Error Codes (RET) 62
Doc.Id. HMSI-216-117
CM CANopen Module for SIMATIC S7-1200
Doc.Rev. 1.00
39 - Acyclic error. Additional error code equals error code from the CANopen
manager.
- -
00h No error
01h Invalid command
02h Module not initialized
03h Invalid Node-ID
04h Invalid length
05h Invalid baud rate
06h General stack init error
07h Invalid NMT command
08h Module in slave mode
09h SDO fragmentation error
0Ah Wrong Mode
0Bh Wrong Backplane
0Ch Invalid function code
0Dh Invalid communication channel
0Eh Communication channel is busy - try again
0Fh State error (command can not be requested in the current state)
10h Parameter error
FCN 1: CAN-ID > 7FFh
FCN 2: Value > maximum number of storable CAN receive messages
CAN_SND: CAN-ID > 7FFh
11h Send error
CAN_SND: Message can not be sent)
FFh General error
41 0X DB could not be deleted because
the “compress user memory” is currently active
the DB to be deleted is currently being copied from the CPU to an
offline project
the H CPU is running coupling or update functions
the WinAC Software CPU has detected an error in the operating sys-
tem of the computer where WinAC is installed
X specifies the offset from DBSTART where the error occurred
SFC23
(for 4100)
8092 (for
4100)
42 0X DB could not be created because
the “compress user memory” is currently active
the number of DBs in the CPU has already reached the maximum pos-
sible number
the H CPU is running coupling or update functions
the WinAC Software CPU has detected an error in the operating sys-
tem of the computer where WinAC is installed
the previous delete action is not completed
X specifies the offset from DBSTART where the error occurred
SFC22
(for 4200)
8092 (for
4200)
43 0X DB number exceeds the maximum number permitted for the CPU.
X specifies the offset from DBSTART where the error occurred
SFC24 80A1
44 00 DB number entered is less than or equal to 0 - -
Error
code
a
Additional
error code
a
Description
SFC/SFB
number
b
RET_VAL
b