Connection version 1:
The 230 V AC mains is connected to the AC2 input (higher priority).
I.e. the battery is spared and the inverter is simultaneously protected against external voltage.
Only if there is no current on AC2, AC1 input switches to power supply by means of the inverter.
Connection version 2:
The inverter is connected to the AC2 input (higher priority). I.e. power is primarily supplied by the
battery over the inverter (e.g. when using solar stand-alone systems). Only when the inverter switches
off due to deep discharge protection, the device switches to 230 V AC mains using the AC1 input.
The Switching Station US-16 must be rmly (e. g. on the wall) attached. The device must
only be put into gear after all the connected cables have been rmly attached. While
running the device there must be no open wire ends or disconnected plugs of any kind.
Please ask authorized personnel if in doubt!