User manual

Technical specifications
For features and intensity of current, please observe the respective type plate of your device!
Working voltage of the battery 12 / 24V DC
Module voltage 5V to 60V DC
Max. module/charge current 10 / 20 / 30 A (type-dependent)
Battery types all 12V or 24V rechargeable lead-acid batteries (open, AGM, gel)
Own consumption, active 15mA
Own consumption, standby < 1mA
Own consumption with load connected 130mA
Final charging voltage, main charging phase 14.1V/28.2V
Charge maintenance 13.7V/27.4V
Load disconnection 10.5V/21.0V
Reconnection 12.5V/25.0V
Temperature compensation -4mA/K/cell
Temperature range -25°C … +60°C
Protection type IP20
Cross section of terminal up to 16mm²
Length of temperature sensor 150cm
Dimensions 190 x 112 x 59mm
Weight 10A: 780g; 20A: 870g; 30A: 890g
Environmental protection note
At the end of its useful life, this product must not be disposed of together with normal household waste, but has to be dropped off at a collection
centre for the recycling of electrical and electronic devices. This is indicated by the symbol on the product, on the instruction manual or on the
packaging.
The materials of which this product is made are recyclable pursuant to their labeling. With the reuse, the recycling of the materials or other forms of
scrap usage you are making an important contribution to the protection of the environment. Please ask your local administration office for the
appropriate disposal center.
Technical specifications are subject to change. We assume no liability for typographical errors. 07/2010
IVT Innovative Versorgungs-Technik GmbH, Dienhof 14, D-92242 Hirschau